Furuno GP-1610CF Manual De Usuario

Descargar
Página de 112
 1-24
1.6 Initial Settings 
Sensor connection
This section should be done with the boat in water.
1. Turn on the power and press the MENU key.
2. Press the [0] key.
3. Press the [5] key to select SENSOR SETUP.
SENSOR SETUP
SPD SENSOR
TEMP SENSOR
SPD CALIB
TEMP CALIB
DEPTH CALIB
        : Cursor                                            : +/-
ESC : Esc
STW        
SOG
OWN       NMEA
-00%(-50~+50)
+000
°
C
+0.0m
Figure 1-34 Sensor setup menu
4. Select source of ship's speed; STW (Speed-Through-Water):
local sensor, SOG (Speed-Over-Ground): GPS.
5. Press ▲ twice to select SPD CALIB.
6. If speed reading is higher or lower than actual speed you may
apply an offset to compensate for this. Enter offset with plus or
minus sign. The 
 key alternately displays plus and minus.
7. If a water temperature sensor is installed, press ▼ to select
TEMP SENSOR.
8. Press t to select OWN. (NMEA is for water temperature data
from external source.)
9. Press ▼ twice to select TEMP CALIB.
10. If temperature reading is higher or lower than actual tempera-
ture you may apply an offset to compensate for this. Enter off-
set with plus or minus sign. The 
 key alternately displays
plus and minus.
11. Press ▼ to select DEPTH CALIB.
12. Enter ship's draft, if applicable. Normally, depth is measured
from the transducer so enter positive figure.
13. Press the MENU key.
Autopilot or remote display connection
1. Press the MENU key.
2. Press the [0] key.
3. Press the [6] key.