Lucent Technologies 555-230-128 Manual De Usuario
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Compact Modular Cabinets
Installation and Test for Compact Modular Cabinets
555-230-128
Issue 3
May 1998
Install and Cable the Cabinets
Page 1-83
Install Multi-point Adapters
1
Basic Multi-point Installation Distances
Figure 1-38
provides cabling information for fanout of ISDN-BRI multi-point
installations. In
Figure 1-38
, the terminating resistor is located in the satellite
closet. All distances assume 24 AWG (#5) (0.26 mm
2
) D-Inside Wire (DIW).
Figure 1-38.
Basic Multi-point with One Work Location
Figure Notes
1. S-interface source (TN556)
2. Terminating resistor
3. Satellite closet
4. Maximum distance from
S-interface source to work location
(1600 feet) (488 m)
(1600 feet) (488 m)
5. Maximum distance from satellite
closet to work location (250 feet)
(76 m)
(76 m)
6. System cabinet
7. Terminating endpoint 1
8. Terminating endpoint 2
9. Work location
10. Maximum distance from information
outlet to terminating endpoint (33
feet) (10 m)
feet) (10 m)
11. Information outlet
2
3
8
9
7
1
10
11
11
5
4
6