Polycom 1500/1800/2000/4000 Manual De Usuario

Descargar
Página de 1101
Polycom®, Inc. 
1069
Appendix M - Homologation for Brazil
H.323 & SIP Protocol Flag Options 
Using a set of system flags, the user has the ability to select either Polycom proprietary or H.323/SIP 
standard protocol settings.
H.323 & SIP Flag Settings
Three flags are enabled on the Collaboration Server, allowing the user to define and select either standard 
or proprietary H.323 and SIP protocol settings. 
Flag name: SIP_TIMERS_SET_INDEX
Description: SIP Timer type timeout settings according to standard or proprietary protocol.
Flag section:   CS_MODULE_PARAMETERS
Possible Values: either 0 or 1.
0 - Polycom standard (flag default setting)
1 - SIP Standard recommendation. For homologation and certification testing, this flag must be set to 1.
For use as a reference, the following table lists the SIP timer types for each flag setting and their 
corresponding timeout values in milliseconds.
SIP Timer Types
SIP TIMER Types
Value (in milliseconds)
POLYCOM (flag default)
Standard Recommended
T1  50000
500
T2  20000
4000
TimerB 35000
32000
TimerC 35000
60000
TimerD 32000
32000
TimerF 35000
32000
TimerH 35000
32000
TimerI 5000
5000
TimerJ 32000
32000
TimerK 5000
5000