To  remove  a  beacon  from  the  Category  II  bracket,  lift  the  latch  and  release 
the pressure from the beacon. The beacon will now be able to slide upwards 
out of the bracket. 
 
It  is  not  anticipated  that  the  LowPro
3
™ 
will  require  servicing  other  than 
cleaning or, rarely, replacement.
 
 
 
Brackets  are  a  key  part  of  the  overall  beacon  system.  They  hold  a  beacon 
ready for deployment while preventing false alarms.  
 
NOTE: Whenever a beacon is returned for service, it must be accompanied 
by the bracket. 
 
10. 
Self-Testing the beacon 
The RLB-37 beacon may be self-tested as is warranted, up to a maximum of 
sixty times in the five-year life of the battery, or once per month for the life of 
the  battery.  Self-Tests  can  be  performed  randomly.  However,  ACR 
recommends  that  you  perform  the  Self-Test  on  a  once  per  month schedule. 
Do  not  exceed  sixty  (60)  Self-Test  cycles  limit  in  the  five-year  life  of  the 
battery, to conserve the battery for emergency use.
 
 
The  functional  Self-Test  is  initiated  by  momentarily 
lifting  the  Activation  Switch  to  a  vertical  position  and 
holding it in this position for at least one second and at 
most  four  seconds.  A  beep  indicates  the  initiation  of 
the  Self-Test  sequence.  Self-Test  will  check  battery 
capacity and perform five functional test sequences as 
described in the digital display Appendix. 
 
The  last  green  LED  indicates  a  successful  test.  If  any  of  the  individual  tests 
fail during Self-Test, there will be two beeps and a red LED flash at the end of 
the Self-Test. Self-Test will discontinue at that point. 
 
NOTE: The  “beeps”  are  a  very  high-pitched  tone  that  some  people  may  not 
be  able  to  hear.  When  performing  the  Self-Test,  you  may  follow  the 
messages on the digital display or you may count the green LED flashes.