Graco 312497F Manual De Usuario

Descargar
Página de 44
Repair 
12
312497F
Section 5: Purging Air After Adding or Replacing a Secondary Divider Valve Module
Steps 1-8, refer to F
1.
Install the new or replacement module to the sec-
ondary divider valve assembly. Also connect the 
tubing or hoses to the appropriate lubrication point if 
the new/replacement module is a base section. 
2.
Do not completely tighten the connection(s) at the 
lubrication point.
3.
Remove the performance indicator or indicator port 
plug from the working valve section on the second-
ary divider valve assembly corresponding to the out-
let port and line connected to a particular lube point.
4.
Attach a hand pump filled with clean, filtered lubri-
cant to the port on the secondary divider valve that 
was opened in Step 3.
5.
Operate the hand pump until air-free lubricant is 
observed flowing from the loosened connector at 
the lube point.
6.
Tighten the fitting at the lube point while lubricant is 
still flowing.
7.
Repeat Steps 3 - 6 for any additional lubrication 
points connected to the new module.
8.
Remove the hand pump and reinstall the perfor-
mance indicator or port plug removed in Step 3 into 
the secondary divider valve’s open port.
The system is now ready for operation.
F
IG
. 10
TI11115
MASTER
HAND PUMP
BLEED HOSE
REMOVE INDICATOR
OR PORT PLUG
SECONDARY
LUBE POINT
HERE
NEW VALVE
BLOCK
BLEED
HERE