Repair
312497F
15
fitting and slowly operate manual pump to verify 
location. If blockage is in this divider valve, go to 
step 7.
6.
Install manual pump into each indicator port of sec-
ondary divider valve in turn and slowly operate 
pump (F
. 13). If high pressure exists, blockage 
has been located. Look for crushed line, tight 
bearing, improperly drilled fittings and/or lube 
inlet port. 
Correct as necessary.
7.
Clean Divider Valve
NOTE: Dirt and foreign material will damage lubricating 
equipment. Perform all service and disassembly under 
the cleanest possible conditions.
a.
Before disassembling any divider valve, make a 
sketch noting the arrangement of Valve Sec-
tions. For example: INLET 10T - 20S - 10T - 
30S - END (F
IG
. 14). Also remove end plugs 
only and try to move each piston back and forth 
without removing the piston from the valve sec-
tion.
b.
If all pistons move freely and there is no indica-
tion of a more serious problem, replace end 
plugs. 
c.
Using a new gasket, tighten and torque as indi-
cated in Table 1 (page 11).
F
IG
. 13
HAND PUMP
SYSTEM PUMP
MASTER
DIVDER
VALVE
SECONDARY
DIVIDER
VALVE
LUBE
OUTLET
INDICATOR PORT
PLUGS REMOVED
BEARING
LUBE OUTLETS
F
IG
. 14
NOTICE
Do not insert hard metal objects into piston bore (i.e., 
punches, screwdrivers, etc.). Hard metal objects can 
damage the surface and cause divider valves to leak 
fluid. Use a brass rod and hand pressure only.
Inlet
10T
20S
10T
30S
End
Table 4: Torque Values (*see F
. 1, page 3)
Assembly Torque (ft-lbs)
MJ
MD
MSP/MH
MX
MXP
MGO
Tie Rod Nuts
12
5-8
23
6-9
12
Indicator Plugs*
6-7
15
8-9
18
12-15
6-8
End Plugs*
11-13
12-15
46
46-50
15
Valve Section 
Mounting Screw
-
-
8-9
-
12-13
-