Application notes
2-wire control (sink)
Speed control 0-20 mA (source)
(a): Run Forward
1.   Connect the ground terminal to the grounding screws located below the output 
terminals. 
2.  Connect the power terminals.
3.  Connect the logic inputs.
4.  Turn on the drive without giving a run command.
5.  Assign factory settings to the drive, 
page 
 set to 
InI.
6.  Set 
tCC
 to 
3C
 see page 
7.  Set the motor parameters (in 
COnF
 mode) only if the factory configuration of the 
drive is not suitable.
8.  Perform an auto-tuning.
9.  Set 
 parameter page 
 to 
EnEG
10. Start
(a) Run Forward
1.  Connect the ground terminal to the grounding screws located below the output 
terminals. 
2.  Connect the power terminals.
3.  Connect the logic input LI1 and analog input AI1.
4.  Turn on the drive without giving a run command.
5.  Assign factory settings to the drive, 
 
page 
 set to 
InI.
6.  Set the motor parameters (in COnF mode) only if the factory configuration of the drive 
is not suitable.
7.  Perform an auto-tuning.
8.  Set 
 to 
OA
 and 
 
page 
 to 0 A. 
Check that 
 page 
 is set to 20 mA.
9.  Start.
LO+
LO-
COM
LI1
LI2
LI3
LI4
+24V
COM
AI1
5V
AO1
R1A
R1B
R1C
R
S
T
U
PA+ PC-
PO
V
W
MODBUS
(a)
(b)
ConF
FULL
EnEG
nPL
I-O-
LO+
LO-
COM
LI1
LI2
LI3
LI4
+24V
COM
AI1
5V
AO1
0-20 mA
R1A
R1B
R1C
R
S
T
U
PA+ PC-
PO
V
W
MODBUS
(a)
ConF
0A
AI1t
AI1-
I-O-
2
1
CrL1
0
AI1-