18
BBV28581  05/2010
General wiring diagram
(1) R1 relay contacts, for remote indication of the drive status.
(2) Internal + 24 V 
c
. If an external source is used (+ 30 V 
c
 maximum), connect the 0 V of the source to the COM terminal, and do not
use the + 24 V 
c
 terminal on the drive.
(3) Reference potentiometer SZ1RV1202 (2.2 k
Ω
) or similar (10 k
Ω  
maximum).
(4) Optional braking module VW3A7005
(5) Optional braking resistor VW3A7
ppp
 or other acceptable resistor. See the possible resistor values in the catalog.
Note: 
• Use transient voltage surge suppressors for all inductive circuits near the drive or coupled to the same circuit (relays, contactors, 
solenoid valves, etc).
• The ground terminal (green screw) is located on the opposite side in comparison with its position on the ATV11 (see wiring trap label).
Single-phase supply 100...120 V
Three-phase supply 200...240 V
ATV12
pppp
F1
Single-phase supply 200...240 V
ATV12
pppp
M2
ATV12
pppp
M3
Source
3-phase 