Control terminals
Characteristics and functions of the control terminals
Terminal
Function
Electrical characteristics
R1A
NO contact of the relay
Min. switching capacity: 
• 5 mA for 24 V 
c
Maximum switching capacity:
• 2 A for 250 V 
and for 30 V 
on inductive load
(cos 
ϕ = 0.4 and L/R = 7 ms)
• 3 A for 250 V 
and 4 A for 30 V 
c
 on resistive load
(cos 
ϕ = 1 and L/R = 0)
• response time: 30 ms maximum.
R1B
NC contact of the relay
R1C
Common pin of the relay
COM
Common of analog and logic I/Os
AI1
Voltage or current analog input
• resolution: 10 bits
• precision: ± 1% at 25°C (77°F)
• linearity: ± 0.3% (of full scale)
• sampling time: 20 ms ± 1 ms
Analog voltage input 0 to +5 V or 0 to +10 V 
(maximum voltage 30 V) impedance: 30 k
Ω
Analog current input x to y mA, impedance: 250 
Ω
5V
+5 VDC power supply for reference potentiometer
• precision: ± 5%
• maximum current: 10 mA
AO1
Voltage or current analog output (collector)
• resolution: 8 bits
• precision: ± 1% at 25°C (77°F)
• linearity: ± 0.3% (of full scale)
• refresh time: 4 ms (maximum 7 ms)
Analog voltage output: 0 to +10 V (maximum voltage +1%)
• minimum output impedance: 470 
Ω
Analog current output: x to 20 mA
• maximum output impedance: 800 
Ω
LO+
Logic output
• voltage: 24 V (maximum 30 V)
• impedance: 1 k
Ω, maximum 10 mA (100 mA in open collector)
• linearity: ± 1%
• refresh time: 20 ms ± 1 ms.
LO-
Common of the logic output (emitter)
LI1
LI2
LI3
LI4
Logic inputs
Programmable logic inputs
• +24 VDC power supply (maximum 30 V)
• impedance: 3.5 k
Ω
• state: 0 if < 5 V, state 1 if > 11 V in positive logic
• state: 1 if < 10 V, state 0 if > 16 V or switched off (not connected) 
in negative logic
• sampling time: < 20 ms ± 1 ms.
+24V
+ 24 VDC supply provided by the drive
+ 24 VDC -15% +20% protected against short-circuits and 
overloads. 
Maximum customer current available 100 mA