Schneider Electric Altivar 12 Manual De Usuario
60
BBV28581 05/2010
Code
Name/Description
Adjustment range
Factory setting
drC-
Motor control menu
(continued)
tUn
M Auto-tuning
nO
DANGER
HAZARD OF ELECTRIC SHOCK OR ARC FLASH
• During auto-tuning, the motor operates at rated current.
• Do not service the motor during auto-tuning.
• Do not service the motor during auto-tuning.
Failure to follow these instructions will result in death or serious injury.
WARNING
LOSS OF CONTROL
• It is essential that the following parameters
UnS
,
FrS
,
nCr
,
nSP
, and
nPr
or
COS
are correctly
configured before starting auto-tuning.
• When one or more of these parameters have been changed after auto-tuning has been performed,
• When one or more of these parameters have been changed after auto-tuning has been performed,
tUn
will
return
nO
and the procedure will have to be repeated.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
nO
YES
dOnE
v
No: When factory parameters of standard motors
v
Yes: Launches auto-tuning
v
Done: If auto-tuning has already been performed
page
and
page
must be
consistent.
• Auto-tuning is performed only if no stop command has been activated. If a freewheel stop or fast stop
function has been assigned to a logic input, this input must be set to 1 (active at 0).
• Auto-tuning takes priority over any run or prefluxing commands, which will take effect after the auto-
tuning sequence.
• Auto-tuning may last for 1 to 2 seconds. Do not interrupt, wait for
tUn
value to change to
dOnE
or
nO
.
Note: During auto-tuning the motor operates at rated current.