Schneider Electric Altivar 12 Manual De Usuario

Descargar
Página de 133
60
BBV28581  05/2010
Code
Name/Description
Adjustment range
Factory setting
drC-
Motor control menu 
(continued)
tUn
Auto-tuning
nO
DANGER
HAZARD OF ELECTRIC SHOCK OR ARC FLASH
• During auto-tuning, the motor operates at rated current.
• Do not service the motor during auto-tuning.
Failure to follow these instructions will result in death or serious injury.
WARNING
LOSS OF CONTROL
• It is essential that the following parameters 
UnS
FrS
nCr
nSP
, and 
nPr
 or 
COS
 are correctly 
configured before starting auto-tuning.
• When one or more of these parameters have been changed after auto-tuning has been performed, 
tUn
 will 
return 
nO
 and the procedure will have to be repeated.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
nO
YES
dOnE
v
No: When factory parameters of standard motors
v
Yes: Launches auto-tuning 
v
Done: If auto-tuning has already been performed
Attention: 
• Auto-tuning must be performed with the motor connected and cold.
• Parameters 
 page 
 and 
 pag
 must be 
consistent.
• Auto-tuning is performed only if no stop command has been activated. If a freewheel stop or fast stop 
function has been assigned to a logic input, this input must be set to 1 (active at 0).
• Auto-tuning takes priority over any run or prefluxing commands, which will take effect after the auto-
tuning sequence.
• Auto-tuning may last for 1 to 2 seconds. Do not interrupt, wait for 
tUn
 value to change to 
dOnE
 or 
nO
.
Note: During auto-tuning the motor operates at rated current.
MPC
Motor parameter choice
nPr
nPr
COS
This parameter allows to choose which motor parameter will be configured (
npr
 or 
CoS
).
v
 page 
v
 page 
I-O-
drC-
CtL-
FUN-
FLt-
COM-