SECTION THREE- TESTING AND MAINTENANCE 
 
1.     Light Leakage Test 
With the IR filter in its operation position (See Figure 3), turn the switch 
ON  and  observe  that  no  light  is  transmitted  through  the  sides  of  the 
case  or  the  flashguard  shield.    Turn  switch  OFF.  No  light  leakage  is 
allowed  in  the  IR  mode.  If  necessary,  replace  the  flashguard  shield 
assembly and repeat the test.  If a new flashguard shield fails to remedy 
the problem, the light is to be condemned and discarded in accordance 
with local procedures. 
 
2.  Flash Rate Test 
a.  Initial 
A  ten  minute  MANUAL  flash  rate  test  is  a  one-time  requirement  for  all 
new MS-2000(M) lights received from supply stock.  This test is required 
for initial acceptance of the light and is conducted to insure that the light 
is capable of sustained operations.   
 
Select the white light function (See Figure 2), turn the switch to ON and 
observe that the strobe lamp flashes.  Allow the light to flash for nine (9) 
minutes, and then manually count the flash rate of the strobe during the 
final  one  minute of  the  test.   This  rate  should  be  50  ±  10  flashes.    It  is 
not necessary to directly observe the light flashes during this evaluation.  
This inspection should be performed in a dark room or enclosure.  
 
If any  light fails to meet the 50 ± 10 flash rate requirements, check the 
batteries  and,  if  necessary,  replace  both  batteries  and  repeat  the  test.  
Additionally,  the  battery  contacts  in  the  battery  well  should  be  checked 
and, if necessary, cleaned with a small brush.  Hold vertical while using 
brush so that any debris falls out of the light.  Repeat the test again.  If 
battery  replacements  or  cleaning  contacts  fail  to  correct  the  problem, 
discard the light in accordance with local procedures. 
 
b.  Periodic 
Normally this test is accomplished in conjunction  with other life support 
survival  kit/vest  test  requirements  and/or  as  required  by  specific 
MAJCOM  directives.  This  test  may  be  accomplished  MANUALLY  or 
AUTOMATICALLY by using the TS-23/A Strobe Light Tester.   
 
If the test is to be conducted MANUALLY, follow the test procedures as 
outlined in paragraph 2a above, except limit the test duration to two (2) 
minutes.    Again,  a  flash  rate  of  50  ±  10  flashes  per  minute  is  the 
acceptable test rate.   
 
If using the TS23/A Strobe Light Tester for this inspection, the light can 
be  tested  in  the  TS-23/A  with  the  IR  filter  in  place,  by  placing  the 
lens/filter over the inspection  window on the TS-23 face label  and then