Silva SEA DATA Manual De Usuario

Descargar
Página de 16
 
Sea Data 
English 
 
 
3.4.  Depth functions (optional) 
To change between Log and Depth information press MODE. This 
function will display depth in metres, feet or fathoms. To change unit 
see 4.2.6. A depth sounder measures the time it takes for a sound 
pulse transmitted from the transducer, to bounce on the bottom and 
be received by the transducer again. The strength of the sound 
pulse decreases with the depth and is also affected  
by temperature and pollution in the water. A soft bottom with a lot of 
vegetation will also decrease the strength of the echo, which can result 
in poor reception by the receiver. If no echo is registrated the depth 
reading will be three dashes i.e. no echo. 
3.4.1. Boat 
speed 
To view boat speed press UP or DOWN until the text BSP is dis-
played. The unit (Knots or Miles/h) is selectable in calibration, see 
4.2.4. 
3.4.2. Shallow 
alarm 
To get to the shallow alarm function, press UP or DOWN until the 
text  
SHALLOW is displayed. To change the alarm value, unlock with KEY
increase/decrease the value with UP/DOWN, move to the next figure 
with MODE button and lock the value again with KEY
3.4.3. Deep 
alarm 
To get to the deep alarm function press UP or DOWN until the text  
DEEP is displayed. To change the alarm value, unlock with KEY,  
increase/decrease the value with UP/DOWN, move to next figure  
with MODE button and lock the value  
again with KEY. The alarm is activated. 
3.4.4. 
Silencing an alarm 
If a shallow alarm limit is reached the instrument will display depth on 
the top row  
and the alarm limit flashing on the bottom row. To silence the alarm 
press any  
button or steer the boat to deeper water. The alarm will be automatically 
activated  
again if the boat is taken to deeper water ( 2 m more than the limit).  
3.4.5. 
Activate / Deactivate an alarm 
To activate / deactivate an alarm, go to the alarm function an press 
UP  and  
DOWN together. If an alarm is active the present alarm value is dis-
played  
together with the text SHA or DEP. If the alarm is deactivated the text 
SHALLOW  
or DEEP is displayed instead. The alarm value is stored in the memory 
even if  
the alarm is deactivated.