Operating Instructions
Before each use, inspect all hoses. If it is evident there is 
excessive abrasion or wear, or the hose is cut, it must be  
replaced prior to using your Broilmaster grill. Call your local 
Broilmaster dealer for a replacement.
Using the Ignitor
Caution:  If a burner fails to light after 5 seconds, turn 
the burner OFF for 5 minutes, to allow the gas to clear, 
then try again.
Note: Each burner must be lit individually.
1.  Turn knob on the grill CLOCKWISE to the OFF posi-
tion.
2.  Turn ON gas at the source.
3.  With the grill lid open, push and turn the burner control 
knob COUNTERCLOCKWISE to Hi.
4.  Push and hold the ignitor button until the burner lights 
(approximately 5 seconds).
5.  If a burner does not light, turn OFF all gas and refer to 
the Troubleshooting section of this manual.
6.  Repeat steps 3 through 5 for other burner.
Using Matches
Caution:  If a burner fails to light after 5 seconds, turn 
the burner OFF for 5 minutes, to allow the gas to clear, 
then try again.
Note: Each burner must be lit individually.
1.  Turn knob on the grill CLOCKWISE to the OFF posi-
tion.
2.  Turn ON gas at the source.
3.  Open the grill lid.  
4.  Insert a burning long wooden match through the lighter 
hole on either side of the grill. See Figure 20.
5.  Turn the burner control knob COUNTERCLOCKWISE 
to HI.  
6.  If a burner does not light, turn OFF all gas and refer to 
the Troubleshooting section of this manual.
7.  Repeat steps 3 through 6 for other burner.
Checking for Gas Leaks
Check for gas leaks every time you connect your Broilmaster
 
 
propane gas grill to a Propane gas cylinder, when a connected 
cylinder has not been used recently, or when either a natural 
or propane grill is being used for the first time. 
Caution:  Do not use an open flame when checking for 
leaks.  Checking for leaks with an open flame may lead 
to a fire or explosion, resulting in property damage or 
personal injury. 
To check for gas leaks:
1.  Use dish washing liquid and a little water to make a soapy 
solution.
2.  Turn OFF the knob on the control panel.
3.  Turn ON the gas at the supply or cylinder.  A hissing sound 
indicates a leak.  Turn OFF the gas and repair the leak.
4.  Apply the soapy water solution to all gas connections.
5.  Look for bubbles.  Bubbles indicate a leak.
6.  If  there  are  bubbles  turn  OFF  the  gas  and  repair  the 
leak.
7.  Turn the gas back ON and repeat the above procedures 
until all leaks are repaired.
Air Shutter Adjustment
The burner (venturi) tube air shutter is preset at the factory 
so that after five minutes the burner flames are blue with well 
defined cones.  If, after five minutes the flame is yellow, or 
there is a gap between the burner and the flame, adjust the 
burner (venturi) tube air shutter as follows:
1.   Turn gas OFF and let the burner cool.
2.  Beneath the control panel you can access the air shutter(s) 
which are located on the end of the burner tubes.
3.   Loosen shutter set screw  
4.   Close the air shutter to the minimum opening. 
5.   Light the burner, wait five minutes and then carefully open 
the air shutter until the flame is blue and well defined.
6.   Retighten the set screw.