Built-in Construction
www.calflamebbq.com
3
Built-in Construction
Read  these  instruction  before  constructing  your  grill 
enclosure.  Failure  to  follow  these  instructions  may  result  in 
damage, injury, or death.
LMS  Inc .  will  not  be  held  responsible  for  property  damage, 
injury,  or  death  as  a  result  of  locating  a  grill  enclosure  in  a 
non-approved  location  or  using  non-approved  construction 
materials .
We strongly recommend that grill owners hire a contractor to construct 
the built-in enclosure. 
In this section:
Location of grill enclosure
• 
Construction materials
• 
Built-in dimensions
• 
Enclosure ventilation
• 
Plumbing for side burners
• 
Electrical supply requirements
• 
Cal Flame grills are designed for outdoor use 
only .
Do not locate your grill enclosure in an enclosed area, 
which is any covered area that is walled on two, three, 
or four sides. This includes areas or rooms such as a 
garage, shed, breezeway, patio, cabana, etc.
Although  some  enclosed  areas  may  have  windows, 
screens, or ventilation systems, they are nevertheless 
considered to be hazardous and may cause damage, 
injury,  or  death.  Enclosed  areas  are  NOT  approved 
for a grill enclosure.
Do  not  locate  your  grill  enclosure  in  any  vehicle, 
including  recreational  vehicles,  campers,  trucks,  or 
boats.
To  reduce  the  risk  of  personal  injury  caused  by 
reaching over a hot appliance, avoid locating cabinet 
storage space directly above the outdoor grill.
Maintain  sufficient  distance  as  to  not  overheat  any 
overhead  combustible  material.  We  recommend  a 
minimum distance of six feet, measured from the top 
of the grill hood. Check with local inspectors and your 
homeowner’s association.
Do  not  locate  your  grill  enclosure  under  a  sealed 
overhead structure.
The  sides,  bottom  and  back  of  the  grill  enclosure 
should  not  be  any  closer  than  24”  to  combustible 
construction.
When planning your Cal Flame grill location, access 
to  gas  lines  and  110V  power  supplies  should  be 
considered.  If you are using natural gas, the location 
with the shortest gas line run is recommended.  You 
may  need  a  grounded,  dedicated,  15A  110V  GFCI 
power source for use of your appliances (e.g. lights, 
rotisserie, refrigerator, receptacles, etc.).
When  determining  a  suitable  location,  consider 
factors such as exposure to wind, proximity to traffic 
paths, and windows that open into the home.
Locate  the  grill  enclosure  any  place  where  there  is 
adequate  ventilation.  The  size  and  configuration  of 
your house and yard will determine how you should 
locate  your  grill  enclosure,  but  as  a  general  rule, 
do not place it under or near windows that can be 
opened into your home.
Location of grill enclosure
DO NOT use combustible materials for the built-in construction .
Construction materials
Acceptable  building  materials:  Brick,  cinder  block,  steel  frame,  hardiboard,  granite,  tile,  glass 
brick, concrete, cement, stucco, stone.
Unacceptable  building  materials:  Wood  of  any  sort,  laminate  or  synthetic  materials,  plastics, 
linoleum, fiberglass.
In addition, we do not recommend using materials that are susceptible to damage or decomposition by 
weather, such as dry wall or plaster.