page 18
CONDITION: No sound, even though 
the amp has power. 
Power LED is on 
without flashing and the amp is receiving an 
input signal. Signal indicator is flashing.
Speakers not connected.
Open circuit due to speaker failure.
CONDITION: No input signal.
(Signal indicator is not flashing even though 
audio is applied and channel is ready).
POSSIBLE REASON:
Input signal level is very low.
Input cables have become disconnected.
There is a short on the amplifier
output. First disconnect your speakers 
from the affected channel(s) one by one 
to determine if one of the loads is 
shorted.
6 Troubleshooting 
CONDITION: Thermal indicator is 
flashing.
POSSIBLE REASON:
The amplifier has become too hot for 
safe operation. Check for loads less than 
2 ohms, and for excessive input levels. 
Check for proper ventilation and proper 
mode-switch setting. Driving low-
impedance loads while in high-voltage 
mode can cause overheating.
CONDITION: All channel thermal 
indicators are flashing.
POSSIBLE REASON:
Power supply thermal overload.
DC or excessive low-frequency signal at 
the amplifier’s output has enabled 
speaker protection.
CONDITION: Bridge LED is flashing
.
POSSIBLE REASON
:
The mode switch was switched while the 
power was on.