Regency IG34 Gas Inbuilt Fireplace
INSTALLATION
Installer Notice: 
These instructions must be left 
with the appliance.
 
After carrying out all adjustments, block the setting screws 
with paint, taking care not to obstruct the breather orifi ce 
of the pressure.
 
Put back the modulator plastic cap.
 
WARNING: To ensure the correct operation of the modu-
lator it is necessary that the plastic cap (A) is returned to 
its original location.
20)  Turn on gas supply and plug in power cord.
21)  At the end of all setting and adjustment operations, check 
electrical installation and gas leaks.
22)  Check operation of fl ame control.
23)  Check for proper fl ame appearance and glow on logs.
C
B
A
18)  Turn on gas supply and plug in
 power cord.
19)  Adjusting the Outlet Pressure
       
   All the adjustments must be 
    carried out in the following order:
 
Remove the modulator plastic cap (A)  using needle nose 
pliers.
 
Maximum pressure: Turn the unit ON to its highest input 
rating. Screw in the nut (B) to increase the outlet pressure 
and screw it out to decrease it. Use a 10 mm wrench.
 
NOTE: The outlet pressure must be set to maximum 2.51 
kPa.
 
Minimum pressure: Remove one of the cables connect-
ed to the electric modulator. While holding the nut (B) with 
a wrench, screw in the screw (C) to increase the pressure 
and screw it out to decrease it. Use a screwdriver 6 x 1 
blade. 
 
NOTE: The outlet pressure must be set to minimum 1.6 
kPa.