Procedure
3A0421A
3
Procedure
1.
Close the dual shutoff handle (E), sample valve (2), 
and solvent valve (C).
2.
Set proportioner to 50% of spray pressure.
3.
Place waster containers under the hardener and 
resin outlets. Open the dual shutoff handle (E). The 
hardener pressure will drop.
4.
First time use:
a.
Open the resin sample valve (2) until you have a 
typical flow or cycle rate.
b.
Adjust the hardener restrictor stem in clockwise 
until the fluid pressure gauges are balanced.
c.
Close the dual shutoff handle (E).
5.
Use after the hardener restrictor stem is pre-set:
a.
Open the resin sample valve (2) until the fluid 
pressure gauges are balanced.
b.
Close the dual shutoff handle (E).
6.
Hold graduated or tared containers under the resin 
outlet fitting (3) and under the hardener outlet tube. 
Open ratio check valve (2) and shut off handle (E) 
and take ratio samples. 
7.
Close the dual shutoff handle (E) when you have 
enough material. Compare amounts in each con-
tainer; amounts should correspond to desired ratio.
NOTE: If you know the mix ratio is by weight, weigh 
tared containers for a more accurate measure. The 
weight ratio will be different than the volume ratio 
unless both fluids have the same specific gravity.
8.
Close the resin valve (2). This valve can be left in 
place for future ratio checks.
9.
Flush the hardener outlet tube with solvent. See mix 
manifold manual for instructions.
10. Remove the ratio check plug (4) and o-ring (5) and 
save for future ratio checks.
11. Reinstall fitting, static mixer, and hose.
NOTE: The hardener restrictor adjustment should 
now be set correctly for spraying mixed material and 
taking ratio checks. No further adjustments are 
required.
NOTICE
To prevent damage to the inlet swivel fittings, use a 
wrench on the front of the mix manifold.