If you detect a leak:
1.  Stop a leak by tightening the loose joint, or by replacing 
the faulty part with a replacement part recommended 
by Coleman. DO NOT attempt to repair the cylinder 
if it should become damaged; the cylinder MUST be 
replaced.
2.  If you are unable to stop a leak, remove the cylinder from 
the grill. DO NOT use the grill until the leak is corrected.
1.  Regularly check the burner venturi tube for blockage 
from an insect nest. Read “Cleaning the Venturi” in the 
section titled “Care, Maintenance, and Cleaning”, and 
also the section titled “Troubleshooting”.
2.  Check that the burner tube [A] is set over the regulator 
outlet [B] correctly. The orifice [C] must be inside the 
venturi. (Fig. 29)
3.  Use only the gas specified.
4.  Keep the grill on a level surface.
How to Check for Leaks
Fixing A Fuel Leak
Start-Up Check List
When to test for leaks:
1.  Perform a leak test each time the gas supply cylinder is 
connected to the regulator. Leak test anytime a part of 
the gas system is replaced.
Failure to follow these safety steps before using the grill 
each time could result in a fire that could be hazardous to 
you, your appliance or property. It is especially important 
to observe these steps after the grill has been stored, 
moved or cleaned.
  WARNING
DO NOT add charcoal or lighting fluid!
  CAUTION
Leak Testing - Disposable LP Gas  
 Cylinders
To Prevent Fire or Explosion Hazard:
•  NO SMOKING. DO NOT use or permit sources of 
ignition in the area while doing a leak test.
•  Perform leak tests outdoors only.
•  NEVER perform a leak test with fire or flame.
  DANGER
Burner and Orifice
 
Check and clean the burner/venturi tubes for insects and 
insect nests. A clogged tube can lead to a fire beneath the 
appliance. (see the section titled “Cleaning the Venturi”)
REPRESENTATIVE ILLUSTRATION
A
C
B
Fig. 29
1.  Make a soapy solution of equal parts mild liquid 
dishwashing detergent and water.
2.  Turn off the burner control knobs.
3.  Apply a soap solution to the connections indicated with 
the arrows. (Fig. 28) If bubbles appear at these areas, a 
leak is indicated.
Fig. 28
No Smoking
No Flame
Fig. 27
Burner
Burner Tube
 
Proper location of the burner with respect to the orifice is 
important. To verify the proper installation of the burner 
tube, use a screwdriver to remove the control panel. The 
burner tube must be located over the orifice fitting. See 
Fig. 27 (control panel not shown).
Orifice Fitting