Desa (V)CD36TNE Manual De Usuario

Descargar
Página de 52
www.desatech.com
116035-01E
31
FIREPLACE 
INSTALLATION
Continued
Ember 
Material
Ember 
Tray
Figure 59 - Applying Ember Material
  WARNING:  The  glass  door 
must be securely in place before 
running this fireplace. Do not run 
this fireplace if glass is missing 
or broken.
4.  Open the bag of ember materials.
5.  Break apart about quarter sized pieces and 
place about a single layer along the full length 
of the ember tray to hide the bottom edge of 
the base log. (see Figure 59).
6.  Replace the glass door and louver panels. See 
Removing/Replacing Glass Door, page 29.
OPERATING FIREPLACE
MILLIVOLT 
FOR YOUR SAFETY  
READ BEFORE LIGHTING
 WARNING: If you do not fol-
low  these  instructions  exactly, 
a  fire  or  explosion  may  result 
causing property damage, per-
sonal injury or loss of life.
A.  This appliance has a pilot which must be 
lighted by hand. When lighting the pilot, 
follow these instructions exactly.
B.  BEFORE LIGHTING smell all around the 
appliance area for gas. Be sure to smell next 
to the floor because some gas is heavier than
air and will settle on the floor.
  WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not 
use any phone in your building.
• Immediately  call  your  gas  supplier 
from a neighbor's phone. Follow the gas 
supplier's instructions.
C.  Use only your hand to push in or turn the 
gas control knob. Never use tools. If the knob 
will not push in or turn by hand, don't try to 
repair it, call a qualified service technician.
Force or attempted repair may result in a 
fire or explosion.
D.  Do not use this appliance if any part has 
been  under  water.  Immediately  call  a 
qualified service technician to inspect the
appliance and to replace any part of the 
control system and any gas control which 
has been under water.
LIGHTING 
INSTRUCTIONS
1.  STOP!  Read  the  safety  information 
above.
2.  Open lower louver panel.
3.  Turn  off  all  electric  power  to  the  fire-
place.
4.  Push in gas control knob slightly and turn 
clockwise to “OFF” (see Figure 60).
5.  Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the 
safety information above. If you don’t smell 
gas go to the next step.
6.  The pilot is located by the main burner and 
should not require accessing for lighting.
7.  Turn gas control knob counterclockwise to       
“PILOT”.
Figure 60 - Control Valve
P
IL
OT
O
F
 PIL
OT
   O
N
T
P
T
H
  
T
P
  
  
T
H
HI
LO
IN
OUT
Gas Control 
Knob
Variable 
Control Knob
Piezo 
Ignitor