 Troubleshooting Your SoundPoint IP / SoundStation IP Phones
5 - 5
MAC address 00f4f200360b. The bootROM log file is uploaded to the boot 
server after every reboot. The application log file is uploaded periodically or 
when the local copy reaches a predetermined size.
Both log files can be uploaded on demand using a multiple key combination 
described in 
 on page 
. The phone uploads four 
files, namely, mac-boot.logapp-boot.logmac-now-boot.log, and 
mac-now-app.log. The “now_” logs are uploaded manually.
The amount of logging that the phone performs can be tuned for the 
application to provide more or less detail on specific components of the 
phone’s software. For example, if you are troubleshooting a SIP signaling 
issue, you are not likely interested in DSP events. Logging levels are adjusted 
in the configuration files or via the web interface. You should not modify the 
default logging levels unless directed to by Polycom Technical Support. 
Inappropriate logging levels can cause performance issues on the phone.
In addition to logging events, the phone can be configured to automatically 
execute command-line instructions at specified intervals that output run-time 
information such as memory utilization, task status, or network buffer 
contents to the log file. These techniques should only be used in consultation 
with Polycom Technical Support.
Application Logging Options
Each of the components of the application software is capable of logging 
events of different severity. This allows you to capture lower severity events 
in one part of the application, while still only getting high severity event for 
other components.
The parameters for log level settings are found in the sip.cfg configuration file. 
They are log.level.change.module_name. Log levels range from 1 to 6 (1 for 
the most detailed logging, 6 for critical errors only). 
When testing is complete, remember to return all logging levels to the default 
value of 4.
There are other logging parameters that you may wish to modify. Changing 
these parameters does not have the same impact as changing the logging 
levels, but you should still understand how your changes will affect the phone 
and the network.
• log.render.level—Sets the lowest level that can be logged (default=1)
• log.render.file.size—Maximum size before log file is uploaded 
(default=16 kb)
• log.render.file.upload.period—Frequency of log uploads (default is 
172800 seconds = 48 hours)
• log.render.file.upload.append—Controls if log files on the boot 
server are overwritten or appended, not supported by all servers