Mitsubishi Electronics E60 Manual De Usuario

Descargar
Página de 415
10. PLC 
CONSTANTS 
10.3 PLC 
Constants 
II - 299 
 
10.3 PLC Constants 
(SETUP PARAM 6. 4/14) 
PLC device 
Item 
Details 
Setting range 
6301 
 
 
 
 
 
 
6348 
R2800,2801
 
 
 
 
 
 
R2894,2895
PLC constant 
Set the value to be set in the data type R 
register used in the PLC program 
(ladder). 
Even if the data is set in the R register 
that corresponds to the PLC side when 
this parameter is displayed‚ the screen 
will not change. Enter a different screen 
once‚ and then select this screen again. 
–99999999 
to 99999999
 
(SETUP PARAM 6. 5/14) 
PLC device 
Item 
Details 
Setting range 
6349 
 
 
 
 
 
 
6396 
R4900,4901
 
 
 
 
 
 
R4994,4995
PLC constant 
Set the value to be set in the data type R 
register used in the PLC program 
(ladder). 
Even if the data is set in the R register 
that corresponds to the PLC side when 
this parameter is displayed‚ the screen 
will not change. Enter a different screen 
once‚ and then select this screen again. 
–99999999 
to 99999999
 
10.4  Selecting the PLC Bit 
(SETUP PARAM 6. 6/14) to (SETUP PARAM 6. 7/14) 
PLC device 
Item 
Details 
Setting range 
6401 
6402 
 
 
 
 
 
 
 
 
6495 
6496 
R2900-Low 
R2900-High 
 
 
 
 
 
 
 
 
R2947-Low 
R2947-High 
Bit selection 
This is the bit type parameter used in the 
PLC program (ladder). 
Even if the data is set in the R register 
that corresponds to the PLC side when 
this parameter is displayed‚ the screen 
will not change.  Enter a different screen 
once‚ and then select this screen again.  
Some of the parameters following #6449 
may be fixed according to the usage 
purpose. 
Refer to the PLC Program Development 
On-board Instruction Manual. 
0: OFF 
1: ON 
 
(SETUP PARAM 6. 7/14) to (SETUP PARAM 6. 9/14) 
PLC device 
Item 
Details 
Setting range 
6497 
6498 
 
 
 
 
 
 
 
 
6595 
6596 
R4400-Low 
R4400-High 
 
 
 
 
 
 
 
 
R4449-Low 
R4449-High 
Bit selection 
expansion 
This is the bit type parameter 
(expansion) used in the PLC program 
(ladder). 
Even if the data is set in the R register 
that corresponds to the PLC side when 
this parameter is displayed‚ the screen 
will not change.  Enter a different screen 
once‚ and then select this screen again.   
0: OFF 
1: ON