2. MACHINING 
PARAMETERS 
2.3 Axis 
Parameters 
II - 11 
 
2.3  Axis Parameters  
Set up the parameter required for each axis. 
Item 
Contents 
Setup range (unit) 
8201  AX. RELEASE 
Select the function to remove the control axis from 
the control target. 
0:  Control as normal.  
1:  Remove from control target. 
0/1 
8202  OT-CHECK OFF 
Select the stored stroke limit II function set in #8204 
and #8205. 
0:  Stored stroke limit II valid  
1:  Stored stroke limit II invalid 
0/1 
8203  OT-CHECK-CANCEL
When the simple absolute position method (#2049 
type is 9) is selected‚ the stored stroke limits I, II (or 
IIB) and IB will be invalid until the first zero point 
return is executed after the power is turned ON. 
0:  Stored stroke limit II valid (according to 
#8202) 
1:  Stored stroke limit II invalid 
Note: Temporary cancel of #8203 soft limit affects 
all the stored stroke limits. 
0/1 
8204  OT-CHECK-N 
This sets the coordinates of the (–) direction in the 
moveable range of the stored stroke limit II or the 
lower limit coordinates of the prohibited range of 
stored stroke limit IIB. 
If the sign and value are the same as #8205, the 
stored stroke limit II (or IIB) will be invalid. 
If the stored stroke limit IIB function is selected, the 
prohibited range will be between two points even 
when #8204 and #8205 are set in reverse.  
When II is selected, the entire range will be 
prohibited. 
±99999.999 (mm) 
8205  OT-CHECK-P 
This sets the coordinates of the (+) direction in the 
moveable range of the stored stroke limit II or the 
upper limit coordinates of the prohibited range of 
stored stroke limit IIB. 
±99999.999 (mm) 
8206  TOOL CHG. P 
Set the coordinates of the tool change position for 
G30. n (tool change position return).  
Set with coordinates in the basic machine 
coordinate system. 
±99999.999 (mm) 
8207 G76/87 IGNR 
(For M system only) 
Select the shift operation at G76 (fine boring) and 
G87 (back boring). 
0:  Shift effective  
1: No shift 
8208 G76/87 (–) 
(For M system only) 
Specifies the shift direction at G76 and G87. 
0:  Shift to (+) direction 
1:  Shift to (–) direction
8209 G60 SHIFT 
(For M system only) 
Set the last positioning direction and distance for a 
G60 (uni-directional positioning) command. 
±99999.999 (mm)