Multi-Tech Systems S000573A Manual De Usuario

Descargar
Página de 38
 
 
 
Using the Router’s Web Interface 
 
14 
 
Configuring which NMEA sentences are sent and when they are sent  
To configure the time interval, additional prefix or ID information, and which NMEA sentences that can be 
sent: 
1.  In the Interval field, type the amount of time, in seconds, that passes before the NMEA information is 
sent. The default is 10 seconds. The range is 1 to 255 seconds. 
2.  You can further identify the router—also called a remote asset—that is collecting and sending the GPS 
information. To do so: 
ƒ 
Add ID The ID is an unique remote asset identification string. The ID string can be any length up to 20 
characters, except that the & and $ are invalid characters. The ID must follow the standard NMEA 
sentence structure. Refer to the Universal IP AT Commands Reference Guide for sentence structure. 
ƒ 
To add more information to the beginning of the ID, in the Add ID Prefix field, type the information. 
3.  You can select which NMEA sentence types you want to send. To do so, check the desired options: GCA, 
GSA, GSV, GLL, RMC, and VTG. 
Configuring the serial port 
Configuring the serial port  
To configure the serial terminal connected to the RS‐232 connector DE9 on the router: 
1.  From Setup, select Serial IP Configuration. 
2.  In the pane that appears, check Enabled
3.  From the Baud Rate drop‐down list, select the baud‐rate at which the serial terminal communicates. The 
default is 115200. 
4.  From the Flow Control drop‐down list, select the flow control for the serial port. The selections are None 
or RTS‐CTS. The default is None. 
5.  From the Parity drop‐down list, select the parity for the serial port. The selections are None, Even, or 
Odd. The default is None.  
6.  To use the Modbus protocol as the protocol the serial devices use to communicate, check Modbus.  
7.  From the Data Bits drop‐down list, select the data bits for the serial port. Data bit selection is 7 or 8. The 
default is 8. 
8.  From the Stop Bits
 
drop‐down list, select the stop bits for the serial port. The selections are 1 or 2. The 
default is 1.