Cisco Systems AS5400 Manual De Usuario

Descargar
Página de 88
6-8
Cisco AS5350 and Cisco AS5400 Universal Gateway Card Installation Guide
78-13311-01
Chapter 6      Troubleshooting
Environment Monitoring
Temperature:
        Temperature Reading:
                Temperature at inlet is measured as 62C/143F.
                Temperature at outlet is measured as 74C/165F.
        Temperature State:
                Temperature is in critical state.
        DFC Busyout/Power-down:
                A DFC is powered down. Slot:1, Type:NP108 DFC
                A DFC is busyout. Slot:2, Type:T1 8 PRI DFC
                A DFC is busyout. Slot:3, Type:NP108 DFC
Fans:
        Fans temperature delta is measured as 6C.
        All fans are running well.
Power Supply:
        Redundant Power System is present.
        RPS Input Voltage status: normal
        RPS Output Voltage status: normal
        RPS Fan status: normal
        RPS Thermal status: normal
        RPS OverVoltage status: normal
Environmental monitor experienced the following events:
        Temperature:sensor failed.
        Fans:monitor dropped.
        Temperature:warning.
        Temperature:sensor recovered.
        Fans:monitor recovered.
        Fans:normal.
        Temperature:critical.
The display below appears on your console when the system reaches a shutdown state:
Router> show environment
Temperature:
        Temperature Reading:
                Temperature at inlet is measured as 70C/158F.
                Temperature at outlet is measured as 82C/179F.
        Temperature State:
                Temperature is in shutdown state.
        DFC Busyout/Power-down:
                A DFC is powered down. Slot:1, Type:NP108 DFC
                A DFC is powered down. Slot:2, Type:T1 8 PRI DFC
                A DFC is powered down. Slot:3, Type:NP108 DFC
Fans:
        Fans temperature delta is measured as 6C.
        All fans are running well.
Power Supply:
        Redundant Power System is present.
        RPS Input Voltage status: normal
        RPS Output Voltage status: normal
        RPS Fan status: normal
        RPS Thermal status: normal
        RPS OverVoltage status: normal
Environmental monitor experienced the following events:
        Temperature:sensor failed.
        Fans:monitor dropped.
        Temperature:warning.
        Temperature:sensor recovered.
        Fans:monitor recovered.
        Fans:normal.
        Temperature:critical.