Moxa Technologies RS-422 Manual De Usuario

Descargar
Página de 79
   
2-2
  
Industio CI-134 Series User’s Manual
Interface Selection Switch SW2 for Port 1/2/3/4:
ON * Set the port interface to RS-485.
OFF  Set the port interface to RS-422.
Data Mode Selection Switch SW1 for Port 1/2/3/4: (Valid if SW2 is ON)
ON * Set the RS-485 port to Automatic Data Direction Control Mode.
OFF Set the RS-485 port to By RTS Mode.
Termination Resistor Port 1/2/3/4 Jumper JP3/4/5/6: (Valid if SW2 is ON)
Open *
Not using Termination Resistor
Shor t Using Termination Resistor
In addition, it has the following default settings for I/O addresses and Interrupt
number:
I/O address: 0x180 (Port 1), 0x188 (Port 2), 0x190 (Port 3), 0x198 (Port 4)
IRQ:
10
INT Vector: 0x1C0
Note !
If the default settings above ar e what you desir ed and good for  the
system without conflicts, you may simply install the boar d in the
system  and  go  dir ectly  to  the  next  chapter ,  “Softwar e
Installation”. Other wise, follow the instr uctions below.
2.  After  you  set  all  the  jumpers  and  switches,  you  should  do  either  the  nor mal
har dwar e installation (detailed in the later section, “Hardware Installation with
IO-IRQ Utility”) or the quick har dwar e installation (detailed right in the next
section, “Quick Hardware  Installation”). The  latter is provided  to facilitate  the
hardware installation, only under the circumstances that:
Only one 
Industio CI-134 Series board is allowed to install in a system.
Windows NT and 95/98 are the only operating systems supported.
CAP J umper  J P1 is shor t and I/O address 0xA700 must be free.
Quick Hardware Installation
To fully utilize the superior feature of flexible hardware configuration design of the
Industio CI-134 Series, a quick and easy method of installation is designed, which
absolutely  saves  you  from  hardware  configuration  effort,  i.e.,  installation
WITHOUT r unning configur ation pr ogr am: Io-ir q.exe
Simply always shor t the