12-19
Catalyst 2960 and 2960-S Switch Software Configuration Guide
OL-8603-09
Chapter 12      Configuring Interface Characteristics
Using Interface Configuration Mode
If you enter multiple configuration commands while you are in interface-range mode, each command is 
executed as it is entered. The commands are not batched and executed after you exit interface-range 
mode. If you exit interface-range configuration mode while the commands are being executed, some 
commands might not be executed on all interfaces in the range. Wait until the command prompt 
reappears before exiting interface-range configuration mode.
Configuring and Using Interface Range Macros
You can create an interface range macro to automatically select a range of interfaces for configuration. 
Before you can use the macro keyword in the interface range macro global configuration command 
string, you must use the define interface-range global configuration command to define the macro. 
Beginning in privileged EXEC mode, follow these steps to define an interface range macro:
Use the no define interface-range macro_name global configuration command to delete a macro.
When using the define interface-range global configuration command, note these guidelines:
  •
Valid entries for interface-range, depending on port types on the switch:
  –
vlan vlan-ID, where the VLAN ID is 1 to 4094 
Note
Although the command-line interface shows options to set multiple VLANs, these 
options are not supported on Catalyst 2960 switches.
  –
fastethernet module/{first port} - {last port}, where the module is always 0
  –
gigabitethernet module/{first port} - {last port}, where the module is always 0
  –
port-channel port-channel-number - port-channel-number, where the port-channel-number 
is 1 to 6
Note
When you use the interface range command with port channels, the first and last 
port-channel number must be active port channels.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
define interface-range macro_name 
interface-range
Define the interface-range macro, and save it in NVRAM.
  •
The macro_name is a 32-character maximum character string.
  •
A macro can contain up to five comma-separated interface ranges. 
  •
Each interface-range must consist of the same port type.
Step 3
interface range macro macro_name 
Select the interface range to be configured using the values saved in 
the interface-range macro called macro_name.
You can now use the normal configuration commands to apply the 
configuration to all interfaces in the defined macro.
Step 4
end
Return to privileged EXEC mode.
Step 5
show running-config | include define
Show the defined interface range macro configuration. 
Step 6
copy running-config startup-config
(Optional) Save your entries in the configuration file.