Cisco Systems 2960 Manual De Usuario

Descargar
Página de 1004
 
12-30
Catalyst 2960 and 2960-S Switch Software Configuration Guide
OL-8603-09
Chapter 12      Configuring Interface Characteristics
Configuring Ethernet Interfaces
Beginning in privileged EXEC mode, follow these steps to configure auto-MDIX on an interface:
To disable auto-MDIX, use the no mdix auto interface configuration command.
This example shows how to enable auto-MDIX on a port:
Switch# configure terminal
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# speed auto
Switch(config-if)# duplex auto
Switch(config-if)# mdix auto
Switch(config-if)# end
Configuring a Power Management Mode on a PoE Port
Note
PoE commands are supported only when the switch is running the LAN base image. Power over Ethernet 
Plus (PoE+) is supported only on Catalyst 2960-S switches. 
For most situations, the default configuration (auto mode) works well, providing plug-and-play 
operation. No further configuration is required. However, use the following procedure to give a PoE port 
higher priority, to make it data only, or to specify a maximum wattage to disallow high-power powered 
devices on a port.
Note
When you make PoE configuration changes, the port being configured drops power. Depending on the 
new configuration, the state of the other PoE ports, and the state of the power budget, the port might not 
be powered up again. For example, port 1 is in the auto and on state, and you configure it for static mode. 
The switch removes power from port 1, detects the powered device, and repowers the port. If port 1 is 
in the auto and on state and you configure it with a maximum wattage of 10 W, the switch removes power 
from the port and then redetects the powered device. The switch repowers the port only if the powered 
device is a Class 1, Class 2, or a Cisco-only powered device.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
interface interface-id
Specify the physical interface to be configured, and enter interface 
configuration mode.
Step 3
speed auto
Configure the interface to autonegotiate speed with the connected device.
Step 4
duplex auto
Configure the interface to autonegotiate duplex mode with the connected 
device.
Step 5
mdix auto
Enable auto-MDIX on the interface. 
Step 6
end
Return to privileged EXEC mode.
Step 7
show controllers ethernet-controller 
interface-id phy
Verify the operational state of the auto-MDIX feature on the interface.
Step 8
copy running-config startup-config
(Optional) Save your entries in the configuration file.