3com S24x Manual De Usuario

Descargar
Página de 156
5-20 
Channelized Data
Configuring Channelized Data  
Configuring Virtual Port Mapping Table
Introduction
A T1 or E1 digital port comprises multiple logical data channels. These channels, 
known as virtual ports, are not associated with any physical slot number and have no 
physical I/O of their own. 
Before You Begin
Obtain the timeslot assignments for all the remote nodes connecting to the 
PathBuilder S24x, 26x, and 27x switch from your network services provider. You 
need this information to complete the virtual ports configuration.
Function
By configuring the Virtual Port Mapping Table, a timeslot channel on a specific T1 
or E1 line is mapped to a virtual port. Virtual ports are numbered from 100 to 254, 
whereas ports with actual physical connections are numbered from 1 to 54. 
Configuration 
Guidelines
The Virtual Port Mapping Table must be configured in conjunction with other 
records as follows.
• Configure the physical port record as either T1 or E1 and all virtual ports 
before you configure the Virtual Port Mapping Table.
• Configure a Virtual Port Mapping Record to assign a timeslot number per 
T1/E1 channel for the application.
What You See 
Figure 5-4 shows the Virtual Port Mapping Table.
Figure 5-4. Virtual Port Mapping Table 
Virtual Port Number
Port Type
T1/E1 Port Number
Timeslot Number
DS0Rate
Node: nodename Address: (blank) Date: ___________Time:__________
Menu: Configure           Path: (Main.6)
1.
Node 
20.