3-22 
PathBuilder S24x, 26x, and 27x Switch Hardware Installation
Cabling the PathBuilder S24x, 26x, and 27x Switch  
Cabling the PathBuilder S24x, 26x, and 27x Switch
Introduction
This section describes the connections for:
• Control Terminal Port (CTP)
• I/O Interface cards
• Network Manager
• LAN
• An external power source
CTP Connection
The CTP is set as Port 6 on the rear of the PathBuilder S24x, 26x, and 27x switch. It 
is a fixed EIA 232-D DCE interface terminating on a DB-25 connector. No special 
cabling is required. Typically, a straight-through DB-25 male to DB-25 male cable is 
required for connection to a terminal device.
I/O Interface Port 
Connection
Three of the I/O ports on the backplane of the PathBuilder S24x, 26x, and 27x switch 
chassis are DB-25 female connectors. One of the I/O ports is a DB-15 female 
connector. You do not need additional cables if the DIM-based ports (Ports 1 and 2) 
have EIA 232-D DIMs installed.
Network Manager 
Connection
The PathBuilder S24x, 26x, and 27x switch supports direct manager connection 
using the CTP. There is a serial interface connection for the SNMP manager. You can 
attach the control terminal to any asynchronous PAD port.
LAN Connection
You can connect a PathBuilder S24x, 26x, and 27x switch to a LAN with a router. 
The router can be either an external router connected to a PathBuilder S24x, 26x, and 
27x switch using a Frame Relay connection or a PathBuilder S200 series switch 
internal router. For more LAN connection information, refer to Appendix A, 
Appendix.
Procedure
Follow these steps to connect to an external power source:
Step
Action
Result/Description
1
Verify that the 115/230 VAC Switch on 
the rear panel is set for the specific 
country’s requirements.
Be sure that the AC power 
cord meets requirements for 
the country of use.
2
If you are using an AC power supply, 
connect the power cord to the back of 
the PathBuilder S24x, 26x, and 27x 
switch enclosure and then to the 
appropriate power source.
If you are using a -48VDC input power 
supply, verify correct polarity with a 
Volt meter.
The PathBuilder S24x, 26x, 
and 27x switch unit automati-
cally powers on and runs self-
diagnostics.