Renesas R5S72623 Manual De Usuario

Descargar
Página de 2152
 
Section 21   IEBus
TM
 Controller 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1125 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
21.3.17
  IEBus Transmit Interrupt Enable Register (IEIET) 
IEIET enables/disables interrupts for sources such as transmit start, transmit normal completion, 
and transmit error completion in IETSR. 
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
R
R/W
R/W
R
R/W
R/W
R/W
R/W
Bit:
Initial value:
R/W:
-
TXSE
TXFE
-
TXEALE
TXE 
TTMEE
TXEROE
TXE 
ACKE
 
 
Bit Bit 
Name 
Initial 
Value R/W 
Description 
 0 
R
Reserved 
This bit is always read as 0. The write value should 
always be 0. 
6 TXSE 0 
R/W
Transmit Start Interrupt Enable 
Enables/disables a transmit start (TXS) interrupt. 
0: Disables a transmit start (TXS) interrupt 
1: Enables a transmit start (TXS) interrupt 
5 TXFE 0 
R/W 
Transmit 
Normal 
Completion Interrupt Enable 
Enables/disables a transmit normal completion (TXF) 
interrupt. 
0: Disables a transmit normal completion (TXF) 
interrupt 
1: Enables a transmit normal completion (TXF) interrupt
 0 
Reserved 
This bit is always read as 0. The write value should 
always be 0. 
3 TXEALE 
R/W 
Arbitration Loss Interrupt Enable 
Enables/disables an arbitration loss (TXEAL) interrupt. 
0: Disables an arbitration loss (TXEAL) interrupt 
1: Enables an arbitration loss (TXEAL) interrupt