Section 15   Serial Communication Interface with FIFO 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 767 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
Error handling
Clear ORER flag in SCLSR to 0
End
Overrun error handling
ORER = 1?
Yes
No
 
Figure 15.16   Sample Flowchart for Receiving Serial Data (2) 
In serial reception, this module operates as described below. 
1.  Reception is started in synchronization with serial clock input or output. 
2.  Receive data is shifted into SCRSR in order from the LSB to the MSB. After the data 
reception, whether the receive data can be loaded from SCRSR into SCFRDR or not is 
checked. If this check is passed, the RDF flag is set to 1 and the received data is stored in 
SCFRDR. If the check is not passed (overrun error is detected), further reception is prevented. 
3.  After setting RDF to 1, if the receive FIFO data full interrupt enable bit (RIE) is set to 1 in 
SCSCR, a receive-data-full interrupt (RXI) request is generated. If the ORER bit is set to 1 and 
the receive-data-full interrupt enable bit (RIE) or the receive error interrupt enable bit (REIE) 
in SCSCR is also set to 1, a break interrupt (BRI) request is generated.