Section 16   Renesas Serial Peripheral Interface 
 
 
Page 828 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
On operation A shown in table 16.7, this module does not detect an error. Whether SPDR can be 
written to or not can be checked using the T[3:0] bits in the buffer data count setting register 
(SPBFDR).  
Likewise, this module does not detect an error on operation B. In a serial transfer that was started 
before the shift register was updated, this module sends the data that was received in the previous 
serial transfer, and does not treat the operation indicated in B as an error. Note that the received 
data from the previous serial transfer is retained in the receive buffer of SPDR, thus it can be 
correctly read. 
Similarly, this module does not detect an error on operation C. To prevent extraneous data from 
being read, the number of receive data units stored in the receive buffer should be read from the 
R[5:0] bits in the buffer data count setting register (SPBFDR). 
An overrun error shown in D is described in section 16.4.6 (1), Overrun Error. A mode fault error 
shown in E is described in section 16.4.6 (2), Mode Fault Error.