Mitsubishi FR-A5AP Manual De Usuario

Descargar
Página de 58
38
(4) Speed detector (PLG)
Line driver LED type PLG
A. A signal 1000ppr to 4096ppr
B. B signal 1000ppr to 4096ppr
Output pulse specifications
P
a
b
c d
2.4 to 5.2V (High)
A
A
B
B
0 to 0.4V (Low)
a, b, c and d should be (1/4 

 1/8)P when rotation is clockwise as viewed from
the shaft end of the PLG.
<Example of PLG available on the market>
Tamagawa Seiki:
TS1508N207, TS5008N122, TS5108N122
Pin Numbers of PLG Output Signals (Tamagawa Seiki, TS1508N207)
Pin Number
Output Signal
Pin Number
Output Signal
C
A-phase signal
H
+5V power supply
R
A-phase inverse signal
K
Power supply common
A
B-phase signal
E
Case earth
N
B-phase inverse signal
Note: When PLG feedback control and orientation control are used together, the PLG is shared between these
controls. Use the PLG with a pulse count is 1000 to 4096ppr.