Vulcan-Hart VULCAN - 36ESB Manual De Usuario

Descargar
Página de 14
GENERAL
INTRODUCTION
This manual is for the Vulcan and Wolf Electric
Salamander Broilers. Procedures in this manual will
apply to all models unless specified. Pictures and
illustrations will be of model 36ESB unless otherwise
noted.
All of the information, illustrations and specifications
contained in this manual are based on the latest
product information available at the time of printing.
INSTALLATION, OPERATION AND
CLEANING
For detailed installation, operation and cleaning
instructions, refer to Installation & Operation Manual
sent with each unit. The manual is also available
online at www.vulcanequipment.com.
NOTE:  Using accessory options, Salamander
broilers can be mounted to the wall, over a range or
placed onto an appropriate table top by using 4" legs.
GRID POSITION AND HEAT
CONTROL SETTING
For detailed information refer to OPERATING THE
BROILER and GRID ADJUSTMENT in the Installation
& Operation Manual.
MODELS
Vulcan
36ESB-208
36ESB-240
36ESB-480
SPECIFICATIONS
 
3 PHASE MACHINE INFORMATION
Model
Total KW
NOMINAL AMPS PER LINE WIRE
OHMS per
Element
208V
240V
480V
X
Y
Z
X
Y
Z
X
Y
Z
36ESB-208
4.5
11.0
18.9
11.0
19.2
36ESB-240
4.5
9.4
16.4
9.4
25.6
36ESB-480
4.5
4.9
8.4
4.9
102.4
NOTES:
1.
Values in the table are nominal. Tolerance is +5/-10%.
2.
Voltage values are @ 60Hz.
3.
Resistance values (ohms) are @ 77° F.
4.
2.25KW per element assembly (left or right).
 
1 PHASE MACHINE INFORMATION
Model
Total KW
NOMINAL AMPS PER LINE WIRE
OHMS per Element
208V
240V
36ESB-208
4.5
21.6
19.2
36ESB-240
4.5
18.8
25.6
NOTES:
1.
Values in the table are nominal. Tolerance is +5/-10%.
2.
Voltage values are @ 60Hz.
3.
Resistance values (ohms) are @ 77° F.
4.
2.25KW per element assembly (left or right).
SALAMANDER ELECTRIC BROILER - GENERAL
Page 3 of 14
F45545 (0315)