Bradford-White Corp 238-42498-00J REV 10/06 Manual De Usuario

Descargar
Página de 40
Internet Version for Reference Only
Installation (Horizontal and Vertical Vent-Air Intake Lengths) continued- 
 
The following components are found in the standard vent and air intake kit, 
P/N 239-42979-00 (kit H).  This kit, as well as all optional vent and air intake 
kits must be ordered separately from the manufacturer shown on the rating 
plate. 
 
4” Vent Tube* 
Vent Terminal Hardware
 
6” Air Intake Tube
 
RTV Silicone Sealant
 
Vent Terminal
 
4” Vent Elbow
 
Inner Wall Term. Mounting Flange
 
6” Air Intake Elbow
 
Outer Wall Term. Mounting Flange
 
 
 
•  The vent and air intake telescopes from 13 3/4” to 23 11/16”. 
 
Table A 
  
 
Horizontal 
"X"
 
16 1/4 
18 
25 1/4 
37 3/4 
61 5/16 
 
 
17 3/16 
20 11/16 
35 3/16 
57 7/8 
107 5/16 
order 
 
order
no add'l 
order 
order 
11 9/16 
kit F 
kit G 
kit req'd 
kit H 
kit I 
16  5/16 
*order 
order 
order 
 
order
order 
17 1/4 
kit F (2) 
kit G & F 
kit F 
kit H & F 
kit F & I 
18  1/16 
order 
order 
order 
 
order
order 
20 3/4 
kit F & G 
kit G (2) 
kit G 
kit G & H  kit G & I 
25  5/16 
order 
 
 
 
 
order
order
order
order
35 1/4 
kit F 
kit G 
kit H 
kit H (2) 
kit I 
38  1/16 
order 
 
 
 
 
order
order
order
order
57 15/16  kit H & F  kit H & G  kit H (2) 
kit H (3) 
kit H & I 
61 3/8 
order 
order 
order 
 
order
order 
Vertical "Y" 
107 3/8 
kit I & F 
kit I & G 
kit I 
kit I & H 
kit I (2) 
 
* (2) = Order two of the kits referenced. 
* (3) = Order three of the kits referenced. 
 
The bold text above show what kit(s) are needed in addition to the standard 
vent and air intake tubes.  If the standard vent and air intake tubes are not 
used in the venting system (those that do not have bold text) they can be 
discarded or saved. 
15