Pressure Switch Testing (cont’d) 
Pressure Switch Testing 
Pressure switch 
wire leads 
With steps 1,2 & 3 
complete, discon-
nect wire leads 
from pressure 
switch.
Use a multi-meter 
set to the ohms 
setting. With 
blower off, check 
across the pres-
sure switch termi-
nals. Are the 
switch contacts 
open (no electrical
continuity)? 
Position the gas 
control power 
switch to the “ON” 
position and adjust 
the thermostat to 
call for heat. This 
will start the 
blower. Check with 
the multi-meter. 
Do the pressure 
switch contacts 
close with the 
blower running? 
The switch contacts 
are OK. See safety 
circuit trace (page 
40).  
Check the tubing and 
pressure tap on switch 
for blockage. Is there 
a blockage? 
Check the tub-
ing and pressure 
tap on switch for 
blockage. Is 
there a block-
age?
Clear blockage
Replace switch 
(see page 27). 
Is the vent 
system
blocked? 
Is vent system 
length within the 
vent table specifi-
cations listed on 
pages 9 & 10?  
Reconfigure vent 
system to be
compliant with 
vent tables. 
See blower 
testing (page 
28). Is the 
Blower OK? 
Correct the 
blower prob-
lem. 
Y
N
N
N
N
N
N
Y
Y
N
Y
Y
Y
26