Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor  
before servicing, unless testing requires power. 
 
 16026795 
©2006 Maytag Services
 
20 
 
Illustration Component 
Testing 
 
Results 
 
 
 
Thermal cutout 
Disconnect all wires from TCO. 
Measure resistance across terminals. 
Cavity TCO............................................
 
Magnetron TCO.....................................  
 
 
Closed at 32
°
F (0
°
C) and  
   Opens at 230
°
F (110
°
C) 
Closed at 140
°
F (60
°
C) and  
   Opens at 320
°
F (160
°
C) 
 
 
Diode 
Discharge Capacitor 
 
Remove diode lead from capacitor and 
connect ohmmeter. 
 
Reverse leads for second test. 
Infinite resistance should be 
measured in one direction and 50K
Ω
 
or more in the opposite direction. 
 
NOTE: Ohmmeter must contain a 
battery of 6 volts minimum. 
 
 
Circuit Protector 
Discharge Capacitor 
 
Remove diode lead from capacitor and 
connect ohmmeter. 
 
Reverse leads for second test. 
Infinite resistance should be 
measured in one direction and 50K
Ω
 
or more in the opposite direction. 
 
NOTE: Ohmmeter must contain a 
battery of 6 volts minimum. 
 
 
Capacitor 
Discharge Capacitor 
 
Remove wires from capacitor terminals 
and connect ohmmeter, set on highest 
resistance scale to terminals. 
 
 
Also check between each terminal and 
capacitor case. 
 
 
Between Terminals: Meter should 
momentarily deflect towards zero 
then return to over 5 M
Ω
. If no 
deflection occurs, or if continuous 
deflection occurs, replace capacitor. 
 
Terminal to Case: Infinite resistance 
 
 
Magnetron 
Discharge Capacitor 
 
Remove wires from magnetron and 
connect ohmmeter to terminals. Also 
check between each terminal and 
ground. 
Between Terminals: Less than 1 
Ω
 
 
Each terminal to ground measures 
Infinite resistance. 
Note: This test is not conclusive. If 
oven does not heat and all other 
components test good replace the 
magnetron and retest. 
 
Blower motor 
Remove all wires from motor. 
 
Measure resistance across coil .............  
 
 
Approximately 31 – 35 
Ω
 
 
Stirrer motor 
Remove all wires from motor. 
 
Measure resistance across terminals ....  
 
 
Approximately 12 – 14 K
Ω
 
 
Filament
Secondary
Primary
 
Transformer 
 
Discharge Capacitor 
Remove all wires from terminals. 
 
Measure resistance from: 
Primary ................................................
Filament ...............................................
Secondary to Ground screw on 
transformer stack .................................  
 
 
 
 
Less than <1 
Ω
 
Less than <1 
Ω
 
 
Approximately 70 – 80 
Ω
 
 
Lamp receptacle 
Test continuity of receptacle terminals. 
Indicates continuity with bulb 
installed. 
 
Wire Harness 
Test continuity of wires 
Indicates continuity