Electrical Connection
To properly install your microwave oven, you must determine the 
type of electrical connection you will be using and follow the 
instructions provided for it here.
Microwave oven must be connected to the proper electrical 
voltage and frequency as specified on the model/serial 
number rating plate. The model/serial number rating plate is 
located on the left-hand side trim.
The microwave oven rated 120/240 volt, 20-amp, has 4 wires 
(L1, L2, N and G) in the flex conduit and should be connected 
to a 20-amp maximum rated circuit, overcurrent protected on 
both the L1 and L2 circuits.
A time-delay fuse or circuit breaker is recommended.
Flexible cable from the microwave oven should be connected 
directly to the junction box.
Do not cut the conduit. The length of conduit provided is for 
serviceability of the microwave oven.
A UL listed or CSA approved conduit connector must be 
provided.
If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the pigtail 
leads.
2. Connect the aluminum wiring to the added section of 
copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.
INSTALLATION INSTRUCTIONS
Prepare Built-In Microwave Oven
1. Locate existing wiring to avoid drilling into or severing wiring 
during installation. 
2. To avoid floor damage, set the microwave oven onto 
cardboard prior to installation. Do not use handle or any 
portion of the front frame for lifting.
3. Remove the shipping materials and tape from the microwave 
oven.
4. Remove and set aside racks and other items from inside the 
microwave oven.
5. Remove the hardware package from inside the bag 
containing literature.
6. Move the microwave oven and cardboard close to the 
microwave oven’s final location.
Make Electrical Connection
This microwave oven is manufactured with a neutral (white) 
power supply wire and a cabinet-connected green (or bare) 
ground wire.
1. Disconnect power.
2. Feed the flexible cable conduit from the microwave oven 
through the opening in the cabinet. 
A. Model/serial number plate
A
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
microwave oven.
Failure to do so can result in back or other injury.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 12 gauge solid copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death, 