Visit our web site at www.cooperlighting.com
Customer First Center  1121 Highway 74 South  Peachtree City, GA  30269  770.486.4800  FAX  770.486.4801    ADH080511 
P H O T O M E T R I C S [ C o m p l e t e   I E S   f i l e s   a v a i l a b l e   a t   w w w . c o o p e r l i g h t i n g . c o m ]
E P L   E N VOY
Test #: EPL-175-MH-RD /   175-Watt Metal Halide / 14,000-Lumen Clear Lamp
Maximum CD Throw
Driving Aisle
30
60
1000
2000
3000
4000
90
E
C
B
D
A
E
C
B
D
A
Test #: EPL-175-MH-SQ /   175-Watt Metal Halide / 14,000-Lumen Clear Lamp
Maximum CD Throw
Driving Aisle
30
60
1400
2800
4200
5600
90
Test #: EPL-175-MH-TG /   175-Watt Metal Halide / 14,000-Lumen Clear Lamp
Maximum CD Throw
Driving Aisle
30
60
1250
2500
3750
5000
90
E
C
B
D
A
36' down driving lane / 26' centered across driving lane
18' down driving lane / centered across driving lane
EPL-175-MH-RD
EPL-175-MH-RD
Fixture type
[60' Wide Bays, 8.5' LC mounting height]   [175W Metal Halide, 14,000 lumens]   [Reflectance: 20% Floor, 0% Walls, 20% Ceiling]
5.89
5.4
0.91
0.95
12.77
8.92
0.68
0.97
Horizontal
Vertical
Ave. fc
Min.fc
Max./Min.
Min.fc @ 5'
Spacing
36' down driving lane / 26' centered across driving lane
18' down driving lane / centered across driving lane
EPL-175-MH-SQ
EPL-175-MH-SQ
5.94
5.45
1.16
1.37
10.09
7.16
0.68
1.15
36' down driving lane / 26' centered across driving lane
*Values are based on entire garage
18' down driving lane / centered across driving lane
EPL-175-MH-TG
EPL-175-MH-TG
Single Row
Double Row
Layout
Single Row
Double Row
Single Row
Double Row
5.96
5.47
1.11
1.19
10.48
7.48
0.78
1.11
F o o t c a n d l e   Ta b l e
Select mounting height and read across
for footcandle values of each
isofootcandle line. Distance in units of
mounting height.
Mounting
Footcandle Values for
Height
Isofootcandle Lines
A
B
C
D
E
10'
5.0
2.0
1.0
0.5
0.2
9'
6.2
2.5
1.2
0.6
0.2
8'
7.8
3.1
1.6
0.8
0.3
F o o t c a n d l e   Ta b l e
Select mounting height and read across
for footcandle values of each
isofootcandle line. Distance in units of
mounting height.
Mounting
Footcandle Values for
Height
Isofootcandle Lines
A
B
C
D
E
10'
5.0
2.0
1.0
0.5
0.2
9'
6.2
2.5
1.2
0.6
0.2
8'
7.8
3.1
1.6
0.8
0.3
F o o t c a n d l e   Ta b l e
Select mounting height and read across
for footcandle values of each
isofootcandle line. Distance in units of
mounting height.
Mounting
Footcandle Values for
Height
Isofootcandle Lines
A
B
C
D
E
10'
5.0
2.0
1.0
0.5
0.2
9'
6.2
2.5
1.2
0.6
0.2
8'
7.8
3.1
1.6
0.8
0.3