Architectural Decorative Vetro Downlight
D02
Page 2 of 2
Evolution, Low Voltage
C3MRDCLW /D3MR02
Zonal Lumens and Percentages
Zone
Lumens
% Lamp %Luminaire
0-30
337
42.14
73.32
0-40
365
45.70
79.51
0-60
416
52.10
90.65
0-90
459
57.47
100.00
40-90
94
11.78
20.49
60-90
43
5.38
9.35
90-180
0
.00
.00
0-180
459
57.47
100.00
** Efficiency = 57.5% **
Certified test report no. 3565FR
Computed by LSI program **TEST-LITE**
SC = .5
Prepared For:
Lightolier
Fall River, MA
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
10%
Wall
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Ro
om C
av
ity R
at
io
0 .68 .68 .68 .68 .67 .67 .67 .67 .64 .64 .64 .61 .61 .61 .59 .59 .59 .57
1 .65 .64 .62 .61 .64 .62 .61 .60 .60 .59 .58 .58 .57 .56 .56 .55 .55 .54
2 .62 .60 .57 .55 .61 .58 .56 .55 .57 .55 .54 .55 .54 .52 .53 .52 .51 .50
3 .59 .56 .54 .51 .58 .55 .53 .51 .54 .52 .50 .53 .51 .49 .51 .50 .49 .48
4 .57 .53 .51 .48 .56 .53 .50 .48 .52 .49 .48 .51 .49 .47 .49 .48 .47 .46
5 .55 .51 .48 .46 .54 .50 .48 .46 .49 .47 .45 .48 .46 .45 .48 .46 .44 .44
6 .53 .49 .46 .44 .52 .48 .46 .44 .48 .45 .43 .47 .45 .43 .46 .44 .43 .42
7 .51 .47 .44 .42 .51 .47 .44 .42 .46 .43 .42 .45 .43 .41 .45 .43 .41 .41
8 .50 .45 .42 .41 .49 .45 .42 .40 .44 .42 .40 .44 .42 .40 .43 .41 .40 .39
9 .48 .44 .41 .39 .48 .43 .41 .39 .43 .41 .39 .43 .40 .39 .42 .40 .39 .38
1 .65 .64 .62 .61 .64 .62 .61 .60 .60 .59 .58 .58 .57 .56 .56 .55 .55 .54
2 .62 .60 .57 .55 .61 .58 .56 .55 .57 .55 .54 .55 .54 .52 .53 .52 .51 .50
3 .59 .56 .54 .51 .58 .55 .53 .51 .54 .52 .50 .53 .51 .49 .51 .50 .49 .48
4 .57 .53 .51 .48 .56 .53 .50 .48 .52 .49 .48 .51 .49 .47 .49 .48 .47 .46
5 .55 .51 .48 .46 .54 .50 .48 .46 .49 .47 .45 .48 .46 .45 .48 .46 .44 .44
6 .53 .49 .46 .44 .52 .48 .46 .44 .48 .45 .43 .47 .45 .43 .46 .44 .43 .42
7 .51 .47 .44 .42 .51 .47 .44 .42 .46 .43 .42 .45 .43 .41 .45 .43 .41 .41
8 .50 .45 .42 .41 .49 .45 .42 .40 .44 .42 .40 .44 .42 .40 .43 .41 .40 .39
9 .48 .44 .41 .39 .48 .43 .41 .39 .43 .41 .39 .43 .40 .39 .42 .40 .39 .38
10 .47 .42 .40 .38 .46 .42 .40 .38 .42 .39 .38 .41 .39 .38 .41 .39 .38 .37
Determined in Accordance with Current IES Published Procedures
Luminaire Input Watts = 52.0
1000
1500
0°
30°
60°
90°
500
Calculite 4” dia. Vetro Downlight,
Cat.# C3MRDCLW/D3MR02
50W G.E. Biax T/E Triple Tube. Lumen Rating = 1200 LMS.
Universal Ballast #C218UNVBES
Candlepower Summary
Angle
Mean CP
Lumens
0
1288
5
1193
110
0
956
15
582
169
20
269
25
88
57
30
51
35
45
28
40
40
45
35
27
50
31
55
27
24
60
23
65
20
20
70
17
75
13
14
80
11
85
7
8
90
6
1000
1500
2000
0°
30°
60°
90°
500
C4MR02
Calculite 4” Dia. Vetro Recessed Downlight,
Cat.# D4MR02
50W G.E. Mr16 NFL (25 deg.) Lamp.
Lumen Rating = 800 LMS. Lightech XFMR LET-75
Candlepower Summary
Angle
Mean CP
Lumens
0
2021
5
1786
165
10
1305
15
870
245
20
418
25
109
80
30
54
35
45
29
40
38
45
33
26
50
29
55
25
23
60
23
65
19
19
70
16
75
13
14
80
10
85
7
8
90
6
Zonal Lumens and Percentages
Zone
Lumens
% Lamp %Luminaire
0-30
489
61.24
80.47
0-40
518
64.81
85.16
0-60
566
70.87
93.12
0-90
608
76.11
100.00
40-90
90
11.29
14.84
60-90
41
5.24
6.88
90-180
0
.00
.00
0-180
608
76.11
100.00
** Efficiency = 76.1% **
Certified test report no. 3601FR
Computed by LSI program **TEST-LITE**
SC = .4
Prepared For:
Lightolier
Fall River, MA
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
10%
Wall
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Ro
om C
av
ity R
at
io
0 .91 .91 .91 .91 .88 .88 .88 .88 .85 .85 .85 .81 .81 .81 .78 .78 .78 .76
1 .87 .85 .83 .82 .85 .83 .82 .80 .80 .79 .78 .77 .76 .76 .75 .74 .73 .72
2 .83 .80 .78 .75 .82 .79 .76 .74 .76 .74 .73 .74 .73 .71 .72 .71 .70 .69
3 .80 .76 .73 .71 .79 .75 .72 .70 .73 .71 .69 .72 .70 .68 .70 .68 .67 .66
4 .78 .73 .70 .67 .77 .72 .69 .67 .71 .68 .66 .69 .67 .65 .68 .66 .65 .64
5 .75 .70 .67 .64 .74 .70 .66 .64 .68 .65 .63 .67 .65 .63 .66 .64 .62 .61
6 .73 .68 .64 .62 .72 .67 .64 .62 .66 .63 .61 .65 .63 .61 .64 .62 .60 .60
7 .71 .65 .62 .60 .70 .65 .62 .59 .64 .61 .59 .63 .61 .59 .63 .60 .59 .58
8 .69 .63 .60 .58 .68 .63 .60 .58 .62 .59 .57 .62 .59 .57 .61 .59 .57 .56
9 .67 .62 .59 .56 .66 .61 .58 .56 .61 .58 .56 .60 .58 .56 .60 .57 .56 .55
1 .87 .85 .83 .82 .85 .83 .82 .80 .80 .79 .78 .77 .76 .76 .75 .74 .73 .72
2 .83 .80 .78 .75 .82 .79 .76 .74 .76 .74 .73 .74 .73 .71 .72 .71 .70 .69
3 .80 .76 .73 .71 .79 .75 .72 .70 .73 .71 .69 .72 .70 .68 .70 .68 .67 .66
4 .78 .73 .70 .67 .77 .72 .69 .67 .71 .68 .66 .69 .67 .65 .68 .66 .65 .64
5 .75 .70 .67 .64 .74 .70 .66 .64 .68 .65 .63 .67 .65 .63 .66 .64 .62 .61
6 .73 .68 .64 .62 .72 .67 .64 .62 .66 .63 .61 .65 .63 .61 .64 .62 .60 .60
7 .71 .65 .62 .60 .70 .65 .62 .59 .64 .61 .59 .63 .61 .59 .63 .60 .59 .58
8 .69 .63 .60 .58 .68 .63 .60 .58 .62 .59 .57 .62 .59 .57 .61 .59 .57 .56
9 .67 .62 .59 .56 .66 .61 .58 .56 .61 .58 .56 .60 .58 .56 .60 .57 .56 .55
10 .65 .60 .57 .55 .65 .60 .57 .55 .59 .56 .54 .59 .56 .54 .58 .56 .54 .53
Determined in Accordance with Current IES Published Procedures
Luminaire Input Watts = 52.0
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.