Lightolier D02 Prospecto

Descargar
Página de 2
Lightolier is a Philips group brand
Job Information 
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group •A0408
Architectural Decorative Vetro Downlight
  D02
Page 2 of 2 
Evolution, Low Voltage
C3MRDCLW /D3MR02
Zonal Lumens and Percentages
Zone
Lumens
% Lamp   %Luminaire
0-30
337
42.14
73.32
0-40
365
45.70
79.51
0-60
416
52.10
90.65
0-90
459
57.47
100.00
40-90
94
11.78
20.49
60-90
43
 5.38
 9.35
90-180
0
.00
.00
0-180
 459
57.47     
100.00
**  Efficiency = 57.5%  **
Certified test report no. 3565FR 
Computed by LSI program **TEST-LITE**
SC = .5 
Prepared For:
Lightolier
 Fall River, MA
 
Tested According to IES Procedures. Test Distance Exceeds Five  
Times the Greatest Luminous Opening of Luminaire.
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
10%
Wall
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Ro
om C
av
ity R
at
io
0 .68 .68 .68 .68 .67 .67 .67 .67 .64 .64 .64 .61 .61 .61 .59 .59 .59 .57
1 .65 .64 .62 .61 .64 .62 .61 .60 .60 .59 .58 .58 .57 .56 .56 .55 .55 .54
2 .62 .60 .57 .55 .61 .58 .56 .55 .57 .55 .54 .55 .54 .52 .53 .52 .51 .50
3 .59 .56 .54 .51 .58 .55 .53 .51 .54 .52 .50 .53 .51 .49 .51 .50 .49 .48
4 .57 .53 .51 .48 .56 .53 .50 .48 .52 .49 .48 .51 .49 .47 .49 .48 .47 .46
5 .55 .51 .48 .46 .54 .50 .48 .46 .49 .47 .45 .48 .46 .45 .48 .46 .44 .44
6 .53 .49 .46 .44 .52 .48 .46 .44 .48 .45 .43 .47 .45 .43 .46 .44 .43 .42
7 .51 .47 .44 .42 .51 .47 .44 .42 .46 .43 .42 .45 .43 .41 .45 .43 .41 .41
8 .50 .45 .42 .41 .49 .45 .42 .40 .44 .42 .40 .44 .42 .40 .43 .41 .40 .39
9 .48 .44 .41 .39 .48 .43 .41 .39 .43 .41 .39 .43 .40 .39 .42 .40 .39 .38
10 .47 .42 .40 .38 .46 .42 .40 .38 .42 .39 .38 .41 .39 .38 .41 .39 .38 .37
Determined in Accordance with Current IES Published Procedures 
Luminaire Input Watts = 52.0
1000
1500
30°
60°
90°
500
Calculite 4” dia. Vetro  Downlight,  
Cat.# C3MRDCLW/D3MR02
50W G.E. Biax T/E Triple Tube. Lumen Rating = 1200 LMS. 
Universal Ballast #C218UNVBES 
Candlepower Summary 
Angle
Mean CP
Lumens
0
1288
5
1193
110
0
956
15
582
169
20
269
25
 88
57
30
 51
35
 45
28
40
 40
45
 35
27
50
 31
55
 27
24
60
 23
65
 20
20
70
 17
75
 13
14
80
 11
85
  7
 8
90
  6
1000
1500
2000
30°
60°
90°
500
C4MR02 
Calculite 4” Dia. Vetro Recessed Downlight,   
Cat.# D4MR02
50W G.E. Mr16 NFL (25 deg.) Lamp.  
Lumen Rating = 800 LMS. Lightech XFMR LET-75 
Candlepower Summary  
Angle
Mean CP
Lumens
0
2021
5
1786
165
10
1305
15
 870
245
20
 418
25
 109
 80
30
  54
35
  45
 29
40
  38
45
  33
 26
50
  29
55
  25
 23
60
  23
65
  19
 19
70
  16
75
  13
 14
80
  10
85
   7
  8
90
   6
Zonal Lumens and Percentages
Zone
Lumens
% Lamp   %Luminaire
0-30
489
61.24
80.47
0-40
518
64.81
85.16
0-60
566
70.87
93.12
0-90
608
76.11
100.00
40-90
90
11.29
14.84
60-90
41
 5.24
 6.88
90-180
0
.00
.00
0-180
 608
76.11
100.00
**  Efficiency = 76.1%  **
Certified test report no. 3601FR 
Computed by LSI program **TEST-LITE**
SC = .4 
Prepared For:
Lightolier
 Fall River, MA
 
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
10%
Wall
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Ro
om C
av
ity R
at
io
0 .91 .91 .91 .91 .88 .88 .88 .88 .85 .85 .85 .81 .81 .81 .78 .78 .78 .76
1 .87 .85 .83 .82 .85 .83 .82 .80 .80 .79 .78 .77 .76 .76 .75 .74 .73 .72
2 .83 .80 .78 .75 .82 .79 .76 .74 .76 .74 .73 .74 .73 .71 .72 .71 .70 .69
3 .80 .76 .73 .71 .79 .75 .72 .70 .73 .71 .69 .72 .70 .68 .70 .68 .67 .66
4 .78 .73 .70 .67 .77 .72 .69 .67 .71 .68 .66 .69 .67 .65 .68 .66 .65 .64
5 .75 .70 .67 .64 .74 .70 .66 .64 .68 .65 .63 .67 .65 .63 .66 .64 .62 .61
6 .73 .68 .64 .62 .72 .67 .64 .62 .66 .63 .61 .65 .63 .61 .64 .62 .60 .60
7 .71 .65 .62 .60 .70 .65 .62 .59 .64 .61 .59 .63 .61 .59 .63 .60 .59 .58
8 .69 .63 .60 .58 .68 .63 .60 .58 .62 .59 .57 .62 .59 .57 .61 .59 .57 .56
9 .67 .62 .59 .56 .66 .61 .58 .56 .61 .58 .56 .60 .58 .56 .60 .57 .56 .55
10 .65 .60 .57 .55 .65 .60 .57 .55 .59 .56 .54 .59 .56 .54 .58 .56 .54 .53
Determined in Accordance with Current IES Published Procedures 
Luminaire Input Watts = 52.0
Tested According to IES Procedures. Test Distance Exceeds Five  
Times the Greatest Luminous Opening of Luminaire.