Enviro 1200 Fireplace Freestanding Manual De Usuario

Descargar
Página de 50
Installation
M
ASONRY
 F
IREPLACE
 I
NSTALLATION
 - I
NSERT
:
Unless you are experienced, we recommend installation by your dealer or a 
professional installer.
It  is  recommended  that  you  install  the  decorative  plates  (if  purchased)  into  the  shrouds 
before installing the unit. Refer to “I
NSTALLATION
 O
F
 D
ECORATIVE
 P
LATES
 - I
NSERT
”.
Install only in a masonry fireplace at least 25” (635 mm) wide, 22” (560 mm) high and 14” (356 mm) 
deep with a good-condition chimney at least 15 ft (4.6 m) high, both of which have been constructed in 
accordance with the building code. Be sure the fireplace and chimney are clean and sound without any 
cracks or loose mortar. Do not remove any bricks or mortar from the fireplace.
If  there  is  a  combustible  floor  in  front  of 
the  masonry  fireplace,  the  fireplace  insert 
must be 8” (203 mm) above the combustible 
floor, and floor protection must be provided 
18” (457 mm) in front of the fireplace insert 
and  8”  (203  mm)  to  each  side  of  the  unit. 
Refer  also  to  S
PECIFICATIONS
  -  C
LEARANCES
  T
O
 
C
OMBUSTIBLES
  -  1200  I
NSERT
  and  S
PECIFICATIONS
 
- C
LEARANCES
 T
O
 C
OMBUSTIBLES
 - 1700 I
NSERT
.
1. Remove any fireplace damper or fasten in 
a permanent open position.
2. (IN CANADA) The stove is vented with 
a 6” stainless steel liner that goes directly to 
the top of the chimney and is covered with 
a  rain  cap.  The  chimney  top  is  sealed  with 
a  flashing  or  steel  plate  that  supports  the 
weight of the chimney liner. The installation 
must  conform  to  the  liner’s  manufacturer’s 
instructions.
This  fireplace  must  be  installed  with  a 
continuous  liner  of  6”  diameter  (CANADA 
ONLY) extending from the fireplace insert to 
the  top  of  the  chimney.  The  chimney  liner 
must conform to the class 3 requirements of 
ULC-S635  Standard  for  Lining  Systems  for 
Existing  Masonry  or  Factory-Built  Chimneys 
and Vents, or ULC-S640 Standard for Lining 
Systems for New Masonry Chimneys.
(IN  U.S.A.)The  appliance  when  installed, 
must  follow  local  building  codes,  in  the 
absence  of  local  building  codes,  with  the 
current  NFPA  211  Standard  for  Chimneys, 
Fireplaces,  Vents,  and  Solid  Fuel-Burning 
Appliances.
Floor
Protection
Combustible Floor
Masonry Fireplace
8"
(203 mm)
Rain Cap
Steel Plate or Flashing
Flexible or Rigid 6"
Stainless Steel Liner
Mantel
Top Facing
Damper Removed
or Fastened Open
Sheet Metal Screws
Fastening Collar to
Stainless Steel Liner
Surround Panel
USA 16” (406 mm)
CND 18” (450 mm)
Figure 31: Insert Installation into existing fireplace with 
hearth.
30