Fig. 12—Wiring Schematics
A00073
FIELD SPLICE
TERMINAL (MARKED)
TERMINAL (UNMARKED)
SPLICE
SPLICE (MARKED)
FACTORY WIRING
FIELD CONTROL WIRING
FIELD POWER WIRING
ACCESSORY OR OPTIONAL
WIRING
TO INDICATE COMMON
POTENTIAL ONLY:
NOT TO REPRESENT WIRING
AHA
ADJUSTABLE HEAT ANTICIPATOR
C
CONTACTOR
CAP
CAPACITOR
CB
CIRCUIT BREAKER
COMP
COMPRESSOR MOTOR
CTD
COMPRESSOR TIME DELAY
DB
DEFROST BOARD
DFT
DEFROST THERMOSTAT
DR
DEFROST RELAY
EQUIP
EQUIPMENT
FU
FUSE
GND
GROUND
HR
HEATER RELAY
HTR
HEATER
IFM
INDOOR FAN MOTOR
LPS
LOW PRESSURE SWITCH
OFM
OUTDOOR FAN MOTOR
QT
QUADRUPLE TERMINAL
RVS REVERSING 
VALVE 
SOLENOID
S.B.
SLOW BLOW FUSE
TC
THERMOSTAT - COOLING
TDR
TIME DELAY RELAY
TH
THERMOSTAT - HEATING
TRAN
TRANSFORMER
NOTES:
1.  IF ANY OF THE ORIGINAL WIRES FURNISHED ARE REPLACED, IT MUST BE
REPLACED WITH TYPE 90 DEGREE C WIRE OR IT’S EQUIVALENT.
2.  SEE PRICE PAGES FOR THERMOSTAT AND SUBBASES.
3.  USE 75 DEGREE COPPER CONDUCTORS FOR FIELD INSTALLATION.
4.  FOR HIGH SPEED IFM, DISCONNECT RED
WIRE FROM TDR 3 AND CONNECT BLK WIRE FROM IFM.
FOR MEDIUM SPEED, DISCONNECT RED WIRE
FROM TDR 3 AND CONNECT BLU WIRE FROM IFM.
5.  DEFROST TIMER TO BE SET AT 90 MINUTES EXCEPT FOR 50JS048, 060 MODELS
SET AT 50 MINUTES.
LEGEND
9