U-Line SS-98 Manual De Usuario

Descargar
Página de 19
U-Line Other Requirements
14
9
Electrical Specifications
WARNING
SHOCK HAZARD — Electrical Grounding Required. 
• Never remove the round grounding prong from the 
plug and never use a two-prong grounding adapter.
• Never use an extension cord to connect power to the 
unit.
IMPORTANT
IMPORTANT
Electrical installation must observe all state and local 
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a 
qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A 
power supply (normal household current). An individual, properly 
grounded branch circuit or circuit breaker is recommended. GFCI 
(ground fault circuit interrupter) is usually not required for fixed 
location appliances and is not recommended for your unit because 
a GFCI could be prone to nuisance tripping. However, be sure to 
consult your local codes.
10 Power Supply
 
 
 
 
 
 
Checking Door Alignment
The unit’s door is aligned at the factory before shipment. However, 
its alignment could have been disturbed during shipment.
IMPORTANT
IMPORTANT
Properly aligned, the door’s gasket should be firmly in 
contact with the cabinet all the way around the door (no 
gaps).
1. Carefully examine the door’s gasket to assure that it is firmly in 
contact with the cabinet.
2. When inspecting door alignment, make sure the door gasket is 
not pinched on the hinge side of the door.
Adjusting Door Alignment
BI-2115
1. Remove top hinge screw pin Remove door by tilting forward 
and lifting off bottom hinge pin.
2. With door upside-down, loosen but do not remove the two 
screws on the door’s bottom hinge plate. 
3. If the top far edge of the door 
needs to move UP, move the 
hinge plate toward the outside 
of the door and retighten 
screws. If the top far edge of 
the door needs to move 
DOWN, move the hinge plate 
toward the inside of the door 
and retighten screws.
4. Mount the door to recheck 
alignment and repeat Steps 2 
and 3 if further adjustment is 
necessary.
5. When top edge of door is 
parallel to top edge of cabinet, 
remove the door and ensure 
the two screws are secure.
6. Remove the door closers 
from the bottom hinge, clean 
thoroughly and lubricate the mating surfaces with petroleum 
jelly.
7. Reinstall the closers, lining up the bosses with holes in hinge and 
hinge plate.
8. Mount the door, install top hinge pivot pin 
All Other Models
1. Loosen (do not remove) top and bottom hinge screws. 
2. Align door squarely with cabinet. Make sure gasket is firmly in 
contact with cabinet all the way around the door (no gaps).
3. Tighten bottom hinge screws.
4. Tighten top hinge screws. 
9 Adjust Door
Door
Closer
Inserts
Boss
Notch 
(must face toward 
center of door) 
Slotted
Mounting
Holes
Raise
Outside
Door Edge
Lower
Outside
Door Edge
23-1/8"
1-1/2"
7"
ADA15IM 
BI95, WH95TP, BI95BTP & BCM95
18-1/2"
Minimum
1-1/2"
7"
21-1/2"
Minimum
4"
7"
BI98 
SS-1095(NF)(FC)(FD)
BI2115
1-1/2"
7"
26-5/16" Minimum
SP18
Acceptable
Location
Preferred
Location
for Receptacle
1-1/2"
7"
24"
1"
7"