Other Site Requirements
8
 
Door Swing Dimensions
All units have a zero clearance for the door to open 90°. U-Line 
recommends a minimum door clearance of 2" to accommodate 
the handle if the unit is installed next to a wall or similar type of 
structure.
Power Supply
Units requires a grounded and polarized 115 VAC, 60 Hz, 15A 
circuit (normal household current). See Electrical Specifications on 
Page 14.
Water Supply
Units require a 1/4” OD water supply line and a shut off valve. For 
more information see page 15
Environmental Requirements
Units are designed to operate between 50°F (10°C) and 100°F 
(37°C). High ambient temperatures (100°F [37°C] or higher) may 
reduce the unit’s ability to reach low temperatures and may also 
reduce the ice production rate for those models with ice makers.
If the ambient temperature is expected to drop below 45°F (7°C), 
drain all water from the unit to prevent freezing damage, which is 
not covered by the warranty.
For best performance, keep the unit out of direct sunlight and away 
from heat generating equipment.
For best performance and life outdoors, place under a counter or 
provide shelter of some kind.
In climates where high humidity and dew points are present, 
condensation may appear on outside surfaces. This is considered 
normal. The condensation will evaporate when the humidity drops.
.
6 Other Site Requirements
Wall
1/4" Min.
20-7/8"
16-1/2"
Door Swing
Wall
2" Min.
20-7/8"
16-1/2"
Door Swing
ADA15IM Series
(Without Handle)
(With Handle)
1/4" Min.
Wall
90°
Door Swing
17-3/8"
16-1/2"
BI98
3/4" Min.
Wall
15-1/8"
15-1/2"
22"
90°
Door Swing
SP18
1/4" Min.
Wall
90°
Door Swing
14-3/8"
15-1/2"
3/4" Min.
Wall
14-3/8"
15-1/2"
90°
Door Swing
SS1095NF
      SS1095FC/FD
WH95, BI95BTP, BCM95