HP ProLiant ML110 G5 Special Tower Server 534458-425 Manual De Usuario

Los códigos de productos
534458-425
Descargar
Página de 31
System Unit
System Unit
System Unit
System Unit
Dimensions 
Dimensions 
Dimensions 
Dimensions (HxWxD)
(with feet)
14.5 x 6.9 x 16.8 in (36.7 x 17.5 x 42.6 cm)
Weight
Weight
Weight
Weight (approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
39 lb (17.5 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
23.81 lb (10.8 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Rated Line Voltage
90 to 132 VAC,
180 to 264 VAC
Rated Input Current
6 A (at 100 VAC),
3 A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
600 W (at 100 VAC),
600 W (at 200 VAC)
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power 365 W (at 100 VAC),
365 W (at 200 VAC)
Maximum Peak Power
385 W (at 100 VAC),
385 W (at 200 VAC)
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.
Non-operating
5% to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
Altitude
Altitude
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
QuickSpecs
HP ProLiant ML110 Generation 5 (G5)
HP ProLiant ML110 Generation 5 (G5)
HP ProLiant ML110 Generation 5 (G5)
HP ProLiant ML110 Generation 5 (G5)
Technical Specifications
DA - 12867   Worldwide — Version 22 — June 2, 2009
Page 26