Cisco Spare 72.3-GB hot-plug SAS drive for Cisco MCS 7845-I2 HDD-7845-I2-72= Hoja De Datos

Los códigos de productos
HDD-7845-I2-72=
Descargar
Página de 9
 
 
Data Sheet 
© 1992-2008 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. 
Page 2 of 10 
High Availability 
High availability on the Cisco MCS 7845-I2 is achieved through the following mechanisms: 
 
Redundant hot-swap 835W power supplies 
 
Hot-swap SAS hard drives configured using Redundant Array of Independent Disks (RAID) 
 
Redundant hot-swap fans 
Memory 
The Cisco MCS 7845-I2 supports up to 48 GB of double-data-rate 2 (DDR2) memory. The 
increased processor performance coupled with DDR memory allows you to retrieve and process 
information fast and efficiently. DDR memory executes twice the number of operations per cycle 
than traditional synchronous dynamic RAM (SDRAM) memory, effectively doubling the data 
exchange rate between memory and processors. 
Variable-Speed Fan Support 
The Cisco MCS 7845-I2 includes variable-speed fans to reduce operating noise. Through the use 
of temperature sensors within the server, the speed of the fans is adjusted to maintain the proper 
cooling, reducing the noise generated by the fans by operating them only when required and at a 
speed based upon the cooling requirements. 
Advanced Connectivity Technology 
The Cisco MCS 7845-I2 supports IBM’s new NetBAY Advanced Connectivity Technology products 
that help reduce Keyboard/Video/Mouse (KVM) costs by linking administrators’ chain systems 
together with Category 5 cable. In addition to reducing overall costs, Advanced Connectivity 
Technology reduces bulk cable clutter, making servers accessible and serviceable in the rack. 
Serviceability 
Light Path Diagnostics 
The Cisco MCS 7845-I2 is equipped with Light Path Diagnostics, which provides a central 
information LED panel (visible without removing the cover) and individual LED lights throughout 
the system on items such as memory dual in-line memory modules (DIMMs), Peripheral 
Component Interconnect (PCI) slots, power supplies, and CPUs. IT can quickly view system 
status, and service personnel can pinpoint a specific failing component, helping reduce downtime 
and service costs. This capability provides increased availability, because nontechnical personnel 
can report error conditions without removing the top cover and exposing vital components to 
further risk. If the system error LED on the front of the server is on, one or more LEDs inside the 
server or on the power supply will be on. These LEDs will help identify and locate problems with 
some server components. By following the path of lights, you can quickly identify the type of 
system error that occurred. The Cisco MCS 7845-I2 is designed so that any LEDs that are 
illuminated remain illuminated when the server shuts down as long as the AC power source is 
good and the power supply can provide +5 VDC to the server. 
Light Path Diagnostics provide indication of failures for the following conditions: 
 
One or both power supplies consuming power higher than maximum rating 
 
Power supply 1 failure 
 
Power supply 2 failure