GB
by a Gas Safe registered installer. During installation 
of this product it is essential to fit an approved gas 
tap to isolate the supply from the appliance for the 
convenience of any subsequent removal or servicing. 
Connection of the appliance to the gas mains or liquid 
gas must be carried out according to the prescribed 
regulation in force, and only after it is ascertained that it 
is adaptable to the type of gas to be used. If not, follow 
the instructions indicated in the paragraph headed 
“Adaptation to different gas types”. On some models 
the gas supply can be connected on the left or on the 
right, as necessary; to change the connection, reverse 
the position of the hose holder with that of the cap and 
replace the gasket (supplied with the appliance). In the 
case of connection to liquid gas, by tank, use pressure 
regulators that conform to the regulation in force. The 
gas supply must be 
connected to the left of 
the appliance. Be sure 
that the hose does not 
pass through the rear of 
the cooker touching hot 
parts.
! Make sure the supply 
pressure conforms 
with the values shown 
in the table entitled 
“Caracteristics of the burners and nozzles”. When 
the cooker is installed between cabinets (recessed), 
the gas connection must be effected by an approved 
flexible hose with bayonet fitting (BS 669 Current 
Edition). The gas inlet for the cookers is a threaded G 
1/2 gas female fitting.
Connecting the gas supply
To make the connection, a flexible hose should be 
used corresponding to the current gas regulations 
which are:
•  the hose must never be at any point in its lenght in 
contact with the “hot” parts of the cooker;
•  the hose must never be longer than 1,5 metre;
•  the hose must not be subject to any tension or 
torsional stress and it must not have any excessively 
narrow curves or bottlenecks;
•  the hose must be easy to inspect along its entire 
length to check its condition;
•  the hose must always be in good condition, never 
attempt to repair.
! The installation must comply with gas safety 
(installation and use) regulations 1984. In all cases for 
the above, by low, a qualified, corgi approved engineer 
must be called for installation.
* Only available in certain models
Electrial connection
Power supply voltage and frequency: 230-240V a.c. 
50/60 Hz.
! The supply cable must be positioned so that it never 
reaches at any point a temperature 50°C higher than 
the room temperature. The cable must be routed away 
from the rear vents. Should you require it, you may 
use a longer cable, however, you must ensure that the 
cable supplied with the appliance is replaced by one 
of the same specifications in accordance with current 
standards and legislation.
Your appliance is supplied with a 13 amp fused 
plug that can be plugged into a 13 amp socket for 
immediate use. Before using the appliance please read 
the instructions below.
WARNING - THIS APPLIANCE MUST BE EARTHED.
THE FOLLOWING OPERATIONS SHOULD BE 
CARRIED OUT BY A QUALIFIED ELECTRICIAN.
Replacing the fuse:
When replacing a faulty fuse, a 13 amp ASTA 
approved fuse to BS 1362 should always be used, and 
the fuse cover re-fitted. If the fuse cover is lost, the 
plug must not be used until a replacement is obtained.
Replacement fuse covers:
If a replacement fuse cover is fitted, it must be of the 
correct colour as indicated by the coloured marking 
or the colour that is embossed in words on the base of 
the plug. Replacements can be obtained directly from 
your nearest Service Depot.
Removing the plug:
If your appliance has a non-rewireable moulded plug 
and you should wish to remove it to add a cable 
extension or to re-route the mains cable through 
partitions, units etc., please ensure that either:
•  the plug is replaced by a fused 13 amp re-wireable 
plug bearing the BSI mark of approval.
or:
•  the mains cable is wired directly into a 13 amp cable 
outlet, controlled by a switch, (in compliance with 
BS 5733) which is accessible without moving the 
appliance.
! For appliances with a rating greater than 13 amp (eg: 
electric hob, double ovens and freestanding electric 
cookers etc.) the mains cable must be wired into a 
cooker output point with a rating of 45 amp. In this 
case the cable is not supplied.
700 mm
HOT PARTS
T he cooker should be connected to the gas-supply 
Gas connection