Indesit KP9F11SKGS Guía Del Usuario

Descargar
Página de 12
GB
5
The switch must be suitable for the charge indicated and 
must comply with current electrical regulations (the earthing 
wire must not be interrupted by the switch). The supply cable 
must be positioned so that it does not come into contact 
with temperatures higher than 50°C at any point. 
Before connecting the appliance to the power supply, make 
sure that:
•  The appliance is earthed and the plug is compliant with 
the law.
•  The socket can withstand the maximum power of the 
appliance, which is indicated by the data plate.
•  The voltage is in the range between the values indicated 
on the data plate.
•  The socket is compatible with the plug of the appliance. 
If the socket is incompatible with the plug, ask an 
authorised technician to replace it. Do not use extension 
cords or multiple sockets.
! Once the appliance has been installed, the power supply 
cable and the electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by 
authorised technicians only.
! The manufacturer declines any liability should these 
safety measures not be observed.
Important: the wires in the mains lead are coloured in 
accordance with the following code:
Green & Yellow   
- Earth
Blue  
 
- Neutral
Brown  
 
- Live
As the colours of the wires in the mains lead may not 
correspond with the coloured markings identifying the 
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked “E” 
or 
 or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked “L” or 
coloured Red.
Connect the Blue wire to the terminal marked “N” or 
coloured Black.
FAILURE TO OBSERVE THE ACCIDENT-PREVENTION 
REGULATIONS  RELIEVES THE  MANUFACTURER  OF 
ALL LIABILITY.
Replacing the cable
Use a rubber cable of the type H05VV-F with a cross section 
of 3 x 1.5 mm². The yellow-green earth wire must be 2 ÷ 3 
cm longer than the other wires.
Gas connection
Connection to the gas network or to the gas cylinder 
may be carried out using a flexible rubber or steel hose, 
in accordance with current national legislation and after 
making sure that the appliance is suited to the type of gas 
with which it will be supplied (see the rating sticker on the 
cover: if this is not the case see below). When using liquid 
gas from a cylinder, install a pressure regulator which 
complies with current national regulations.
! Make sure that the gas supply pressure is consistent 
with the values indicated in the Table of burner and nozzle 
specifications (see below). This will ensure the safe 
operation and durability of your appliance while maintaining 
efficient energy consumption. 
Gas connection using a flexible rubber hose
Make sure that the hose complies with current national 
legislation. The internal diameter of the hose must measure: 
8 mm for a liquid gas supply;13 mm for a methane gas 
supply. 
Once the connection has been performed, make sure that 
the hose:
•  Does not come into contact with any parts which reach 
temperatures of over 50°C.
•  Is not subject to any pulling or twisting forces and that it 
is not kinked or bent.
•  Does not come into contact with blades, sharp corners 
or moving parts and that it is not compressed.
•  Is  easy  to  inspect  along  its  whole  length  so  that  its 
condition may be checked.
•  Is shorter than 1500 mm.
•  Fits firmly into place at both ends, where it will be fixed 
using clamps which comply with current regulations.
! If one or more of these conditions is not fulfilled or if the 
cooker must be installed according to the conditions listed 
for class 2 - subclass 1 appliances (installed between two 
cupboards), the flexible steel hose must be used instead 
(see below).
Connecting a flexible jointless stainless steel pipe to 
a threaded attachment
Make sure that the hose and gaskets comply with current 
national legislation. To begin using the hose, remove the 
hose holder on the appliance (the gas supply inlet on the 
appliance is a cylindrical threaded 1/2 gas male attachment).
! Perform the connection in such a way that the hose length 
does not exceed a maximum of 2 metres, making sure that 
the hose is not compressed and does not come into contact 
with moving parts.
Checking the connection for leaks
When the installation process is complete, check the hose 
fittings for leaks using a soapy solution. Never use a flame.