Indesit P640A [multilanguage] Guía Del Usuario

Descargar
Página de 12
9
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nomin.
Ridot.
(mm)
(mm)
***
**
(mm)
Fast (R)
100
3,00
0,70
41
86
218
214
116
286
Semi Fast (S)
75
1,90
0,40
30
70
138
136
106
181
Auxiliary (A)
55
1,00
0,40
30
50
73
71
79
95
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
**
At 15°C and 1013 mbar-dry gas
**
Propane P.C.S. = 50.37 MJ/kg.
***
Butane P.C.S. = 49.47 MJ/kg.
Natural P.C.S. = 37.78 MJ/m
3
Mains frequency and voltage of the electrical section
and characteristics of the gas section
Model
Gas section
Electric
section
Class Rated power kW (1)
Voltage
P 640 A GB
II2H3+
7,8 (567 gr/h-G30)
     (557 gr/h - G31)
230V~
50-60Hz
(1) The values in g/h refer to the capacities with liquid
gas (Butane, Propane).
This appliance conforms with the following European Economic Community directives:
-
73/23/EEC of 19/02/73 (Low Voltage) and subsequent modifications;
-
89/336/EEC of 03/05/89 (Electromagnetic Compatibility) and subsequent modifications;
-
90/396/EEC of 29/06/90 (Gas) and subsequent modifications;
-
93/68/EEC of 22/07/93 and subsequent modifications.
S
S
A
R
P 640 A ... GB
Characteristic of the burners and nozzles