Indesit KP9F11S(K)/G Guía Del Usuario

Descargar
Página de 12
GB
5
Burner and nozzle specifications
 
DATA PLATE
 
Dimensions 
HxWxD
 
32x54x38 cm
 
Volume
 
68 l
 
Burners
 
may be adapted for use with any 
type of gas shown on the data plate
 
Electrical 
connections
 
voltage: 220-240V ~ 50/60Hz 
maximum power absorbed 2400W
 
ENERGY LABEL
 
Directive 2002/40/EC on the label 
of electric ovens Norm EN 50304 
 
Declared energy consumption for 
Natural convection Class – heating 
mode:            Static 
 
 
This appliance conforms to the 
following European Economic 
Community directives:  
2006/95/EEC of 12/12/06 (Low 
Voltage) and subsequent 
amendments; 
- 89/336/EEC of 03/05/89 
(Electromagnetic Compatibility) 
and subsequent amendments; 
- 93/68/EEC of 22/07/93 and 
subsequent amendments. 
- 2002/96/EC 
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By-pa-
ss
1/100
(mm)
Nozzle
1/100
Flow*
g/h
Nozzler
1/100
Flow*
l/h
Nom.
Red.
(mm)
G30/31
(mm)
Fast
(Large) (R)
100
3.00
0.7
40
86
218
116
286
Semi Fast
(Medium) (S)
75
1.65
0.4
30
64
120
96
157
Auxiliary
(Small) (A)
55
1.00
0.4
30
50
73
71
95
Triple Crown (TC)
130
3.25
1.3
57
91
236
124
309
Supply pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
20
17
25
* At 15°C and 1013 mbar-dry gas
Propane G31
H.s. = 50,37 MJ/kg
Butane G30
H.s. = 49,47 MJ/kg
Methane G20
H.s. = 37,78 MJ/m
3